1-20 of 102 Search Results for

TRSSSV

Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Images
Images
Images
Images
<b>TRSSSV</b> safety depth location ±20 m below pile depth.
Published: 25 September 2011
Fig. 9 TRSSSV safety depth location ±20 m below pile depth. More
Images
Images
22 ft burn shoe assembly to remove scale from <b>TRSSSV</b>
Published: 23 March 2010
Figure 5 22 ft burn shoe assembly to remove scale from TRSSSV More
Images
HOS and burn shoe assembly in relation to <b>TRSSSV</b> flapper
Published: 23 March 2010
Figure 6 HOS and burn shoe assembly in relation to TRSSSV flapper More
Images
Images
Journal Articles
J Pet Technol 63 (02): 65–67.
Paper Number: SPE-0211-0065-JPT
Published: 01 February 2011
... in the UK sector of the North Sea developed a blockage in the safety-valve control line that rendered the existing tubing-retrievable subsurface safety valve (TRSSSV) inoperable. Also, the sealbores inside the valve were scarred and damaged badly enough that a conventional wireline safety valve would...
Proceedings Papers

Paper presented at the International Petroleum Technology Conference, March 26–28, 2013
Paper Number: IPTC-16576-MS
..., sub-surface safety valve is a critical component of the asset integrity management program for these gas wells. In order to meet the requirements of completion design and reservoir pressure, the world's first 9-5/8in 10,000psi rated TRSSSV were developed tested and qualified for these developments...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, October 8–10, 2012
Paper Number: SPE-159202-MS
...Fig. 1 Non-self equalizing TRSSSV. ...
Proceedings Papers

Paper presented at the SPE/ICoTA Well Intervention Conference and Exhibition, March 26–27, 2019
Paper Number: SPE-194267-MS
... recovered from the plug but while retrieving the 3.813" plug with a 4" GS pulling tool, the lock mandrel was released from the 3.813" SC-TRSSSV profile, however, possibly due to insufficient equalization time, the plug slipped down below the profile and broke the slickline wire. The plug dropped down...
Journal Articles
J Pet Technol 37 (10): 1813–1818.
Paper Number: SPE-12193-PA
Published: 01 October 1985
... a component failure rate appeared to have significant influence on the results a range of values was used in the calculation. System Definition The standard production well completion for the Kuparuk field (Fig. 1) has a tubing-retrievable subsurface safety valve (TRSSSV) installed at approximately 2,000 ft...
Journal Articles
J Pet Technol 62 (06): 71–72.
Paper Number: SPE-0610-0071-JPT
Published: 01 June 2010
..., originally prepared for the 2010 SPE/ICoTA Coiled Tubing and Well Intervention Conference and Exhibition, The Woodlands, Texas, 23-24 March. Problems with the tubing-retrievable subsurface safety valve (TRSSSV) and the subsea-tree valves resulted in a completion workover being scheduled. Before pulling...
Proceedings Papers

Paper presented at the SPE/ICoTA Coiled Tubing and Well Intervention Conference and Exhibition, March 23–24, 2010
Paper Number: SPE-130682-MS
...Figure 4 TRSSSV hold open sleeve ...
Proceedings Papers

Paper presented at the Abu Dhabi International Petroleum Exhibition & Conference, November 12–15, 2018
Paper Number: SPE-192711-MS
...Figure 12 Image of detached TRSSSV flapper at NO-GO profile ...
Journal Articles
J Pet Technol 59 (09): 60–62.
Paper Number: SPE-0907-0060-JPT
Published: 01 September 2007
... with an overshot and conventional packer. Field experience demonstrated that the early concerns about the pas- sage of cement and plugs through an unprotected tubing-retrievable sub- surface safety valve (TRSSSV) have proved to be unfounded. To date, no serious problems with the TRSSSV have been experienced...
Proceedings Papers

Paper presented at the SPE Middle East Oil and Gas Show and Conference, September 25–28, 2011
Paper Number: SPE-142410-MS
...Fig. 9 TRSSSV safety depth location ±20 m below pile depth. ...
Images
Horizontal single‐trip multistage ball‐drop completion (after Zwarich et al...
Published: 10 September 2020
Fig. 5 Horizontal single‐trip multistage ball‐drop completion (after Zwarich et al. 2018 ). TRSSSV = tubing retrievable subsurface safety valve; TVD = true vertical depth. More

Product(s) added to cart

Close Modal