1-20 of 14784 Search Results for

Minimum ID

Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Images
Effect of circulating kill rate on <span class="search-highlight">minimum</span> separator <span class="search-highlight">ID</span>.
Published: 01 December 1991
Figure 7 Effect of circulating kill rate on minimum separator ID. More
Images
<span class="search-highlight">Minimum</span> flow rate through a 4.892&quot; <span class="search-highlight">ID</span> horizontal pipe necessary to keep a 6...
Published: 06 February 2012
Fig. 11 Minimum flow rate through a 4.892" ID horizontal pipe necessary to keep a 600μm proppant particle afloat and transported More
Images
Proceedings Papers

Paper presented at the SPE/ICoTA Well Intervention Conference and Exhibition, March 26–27, 2019
Paper Number: SPE-194259-MS
... these challenges, an accurate simulated lockup depth is estimated using historical data to identify the required pull force. The CT slim tractor (2 1/8-in.) was chosen as the optimum tool to provide the required pull force, as well as pass through the minimum ID restriction of the well. Specially designed tapered...
Proceedings Papers

Paper presented at the SPE 2022 Symposium Compilation, December 14, 2022
Paper Number: SPE-210496-MS
... for a reentry by drilling out cement plugs set below the mudline inside the 9⅝-in. outside diameter (OD), 8.535-in. minimum inside diameter (ID), casing and permanently abandoning the wells by isolating the annular space that communicated with the open hole and extended to the mudline. Operations had...
Proceedings Papers

Paper presented at the ADIPEC, October 31–November 3, 2022
Paper Number: SPE-211144-MS
... Abstract The case studies performed in the Middle East and South Asia region shared in the paper reflect the requirement of production/injection enhancement in challenging downhole conditions. Larger tubing diameter, limitations of minimum ID to deploy bigger OD tools, low bottom hole pressures...
Journal Articles
J Pet Technol 35 (09): 1617–1623.
Paper Number: SPE-11185-PA
Published: 01 September 1983
... protective scales, oxides, and/or corrosion inhibitor films. Therefore, calculation of the erosional velocity and the proper sizing of the tubing ID is a critical facet in mitigating the aggressiveness of a corrosive environment. The calculation of the erosional velocity and the minimum ID for a well...
Proceedings Papers

Paper presented at the Offshore Technology Conference, August 16–19, 2021
Paper Number: OTC-31319-MS
... in the casing, or to know the minimum internal diameter (ID) and pressure ratings of the casing. But evaluating the outer (second) casing geometry is a completely new idea and yet very important for many reasons. If the outer pipe is deformed, it will eventually cause the inner pipe to deform, compromising...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 30–October 2, 2019
Paper Number: SPE-195913-MS
... isolation being discussed in a separate paper). Last paper gave insight about plug passing through a minimum ID of 2.3" and set in a 7" production casing. After this campaign, more candidates with plug setting section of 9-5/8" Casing &amp; 4-1/2" Screens were selected. Plug setting with Coil Tubing &amp; E...
Proceedings Papers

Paper presented at the Abu Dhabi International Petroleum Exhibition & Conference, November 13–16, 2017
Paper Number: SPE-188853-MS
... was the inherent risk of permanently damaging the formation. The existing completion design required the isolation plug to pass through a minimum ID of 2.3" and set in a 7" production casing. For this reason, high expansion ratio retrievable inflatable plugs were proposed. The waxy nature of the reservoir fluid...
Proceedings Papers

Paper presented at the Offshore Technology Conference, April 30–May 3, 2001
Paper Number: OTC-13287-MS
... that no formation damage would be sustained. The operation had to be run from a semi-submersible platform that was set in a water depth of 430 ft. (2 nd d job performed in a water depth of 968 ft.) The gun assembly would have to pass through a 2.81-in. minimum ID. Introduction For twenty years...
Proceedings Papers

Paper presented at the SPE Latin American and Caribbean Petroleum Engineering Conference, March 25–28, 2001
Paper Number: SPE-69519-MS
... of 430 ft. (2 nd job performed in a water depth of 968 ft.) The gun assembly would have to pass through a 2.81-in. minimum ID. He two jobs were completed under live well conditions, and both were successful. The estimated cost saving from elimination of 3 days of rig time for the second job...
Images
Dimensioned images of partially closed fluid loss isolation valve. Measurem...
Published: 03 September 2019
Figure 22 Dimensioned images of partially closed fluid loss isolation valve. Measurements reveal a minumim ID of approximately 3.74 inches compared with the expected minimum ID of 4.615 inches. More
Proceedings Papers

Paper presented at the SPE Asia Pacific Oil & Gas Conference and Exhibition, November 17–19, 2020
Paper Number: SPE-202257-MS
... deployment hydraulic tractor lockup depth cttractor combine acid stimulation mfiv expansion ratio overcome reach issue minimum id circulation sub Introduction Covering maximum possible or preferably full open hole (OH) interval during CT matrix acid stimulation of extended reach wells (ERWs...
Images
Multi-Finger Processed log and 3D view – Frac sleeve #1 found open with obs...
Published: 23 April 2018
Fig. 8 Multi-Finger Processed log and 3D view – Frac sleeve #1 found open with obstruction of minimum ID of 2.8". More
Journal Articles
J Pet Technol 62 (04): 56–58.
Paper Number: SPE-0410-0056-JPT
Published: 01 April 2010
... normally is used for these operations. Island Frontier was the vessel used in this operation. The subsea lubricator system used for this operation consists of four main elements with minimum inside diameter (ID) of 7 1 / 16 in. The first element is the lower intervention package including the subsea...
Proceedings Papers

Paper presented at the SPE/ICoTA Well Intervention Conference and Exhibition, March 26–27, 2019
Paper Number: SPE-194290-MS
.... A majority of the through tubing sidetracks have been drilled using conventional monobore or through-tubing whipstocks in multiple configurations. CTD has been limited to the size of the tubing or minimum internal diameter (ID) that a whipstock can pass-through and the ID of the tubing, liner, or casing...
Proceedings Papers

Paper presented at the SPE/ICoTA Coiled Tubing and Well Intervention Conference and Exhibition, March 27–28, 2018
Paper Number: SPE-189912-MS
... milling job. Several operational challenges, such as excessive corrosion at a minimum MHA ID, pitting on bottomhole assembly (BHA) components and erosion on ball seats, erosion, and degradation of elastomeric seals at a BHST of 400 °F, were observed. These adverse effects were avoided with engineering...
Proceedings Papers

Paper presented at the SPE/ICoTA Coiled Tubing and Well Intervention Conference and Exhibition, March 22–23, 2016
Paper Number: SPE-179103-MS
... (minimum ID 3.2") and the 2 nd build up was at 3790-3820 mBRT (minimum ID 2.9"). This scale restricted the reperforating tools from reaching the targeted zone as 89% of the major gas contributor layers were below the 2 nd build up. Scale milling was planned to allow 3-1/8" gun (with possible swelling...
Journal Articles
Journal: SPE Journal
SPE J. 26 (02): 1050–1071.
Paper Number: SPE-203824-PA
Published: 14 April 2021
... Longifolia (ML), and potato starch (PS) on pressure drop, shear viscosity, and flow behavior index ( n ) was experimentally investigated. Minimum pressure drop occurred in the 0.0508-m-inner-diameter (ID) pipeline because of the combined consequence of temperature and 2,000 ppm ML during the transportation...

Product(s) added to cart

Close Modal