1-20 of 23 Search Results for

MFCT

Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Images
Ultrasonic (a), <span class="search-highlight">MFCT</span> Logs (b) And Camera Images Of ICD #34 (c)
Published: 10 November 2014
Figure 9 Ultrasonic (a), MFCT Logs (b) And Camera Images Of ICD #34 (c) More
Images
<span class="search-highlight">MFCT</span> measured casing shape and calculated casing shape (&quot;initial ellipse&quot;)
Published: 09 November 2020
Figure 3 MFCT measured casing shape and calculated casing shape ("initial ellipse") More
Images
<span class="search-highlight">MFCT</span> measured casing shape and improved calculated casing shape (&quot;final ell...
Published: 09 November 2020
Figure 5 MFCT measured casing shape and improved calculated casing shape ("final ellipse") More
Images
<span class="search-highlight">MFCT</span> interpretation and stiff-string simulation results
Published: 09 November 2020
Figure 12 MFCT interpretation and stiff-string simulation results More
Proceedings Papers

Paper presented at the Abu Dhabi International Petroleum Exhibition & Conference, November 9–12, 2020
Paper Number: SPE-202828-MS
...Figure 3 MFCT measured casing shape and calculated casing shape ("initial ellipse") ...
Journal Articles
J Pet Technol 67 (11): 105–106.
Paper Number: SPE-1115-0105-JPT
Published: 01 November 2015
... in production at the heel had replaced the nearly straightline pro- duction profile originally observed. Ini- tially, this was thought to be the result of scale or salt deposits because the current and prior log had also seen an increase in the gamma ray readings. A multifinger caliper tool (MFCT) was run...
Proceedings Papers

Paper presented at the SPE/IADC Drilling Conference and Exhibition, March 14–16, 2017
Paper Number: SPE-184634-MS
... string, which included a stabilizer at the top, followed by MWD transmission and controller modules, directional sensor, PWD sensor, and strain gauges below. A multifunction circulating tool (MFCT) was installed on top of the MWD toolstring. The MFCT contained a swivel that enabled the rotation of only...
Proceedings Papers

Paper presented at the SPE/PAPG Annual Technical Conference, November 22–23, 2011
Paper Number: SPE-156207-MS
... Inspection EMDS measures wall thickness and monitors any metal loss of first and second pipes. Combined with Multi Finger Caliper Tool (MFCT), it can also monitor precisely internal diameter condition of the pipe. The tool string run consisted of 24 Arm Multi finger caliper and Electromagnetic...
Proceedings Papers

Paper presented at the Abu Dhabi International Petroleum Exhibition & Conference, November 7–10, 2016
Paper Number: SPE-183386-MS
... to measure the final casing profile. The MFCT provider processes the data and usually delivers a “Maximum Diameter” log with one value per joint (or in some cases per meter) for both MFCLs. Theoretically, the difference in max. diameter represents the wear groove depth. The methodology is illustrated...
Proceedings Papers

Paper presented at the Abu Dhabi International Petroleum Exhibition & Conference, November 11–14, 2019
Paper Number: SPE-197517-MS
... may not be copied. The abstract must contain conspicuous acknowledgment of SPE copyright. Nomenclature Nomenclature Abbreviation Expansion API American Petroleum Institute CI Corrosion inhibitor GOR Gas-oil-ratio HSE Health, safety and environment MFCT Multi-finger...
Proceedings Papers

Paper presented at the International Petroleum Technology Conference, January 19–22, 2014
Paper Number: IPTC-17465-MS
... to ensure wellbore integrity is maintained. Tubing Inspection: 8 IPTC 17465 Sour Wells: No tubing inspection is required in sour wells. Sweet Wells: Run the Multi-Finger Caliper Tool (MFCT) to detect any sweet gas corrosion as follows: Run MFCT base log on all new sweet gas wells before producing...
Proceedings Papers

Paper presented at the SPE Offshore Europe Conference & Exhibition, September 5–8, 2017
Paper Number: SPE-186153-MS
... not be copied. The abstract must contain conspicuous acknowledgment of SPE copyright. Abbreviations Abbreviations Abbreviations: Expansion BVS Barrier Verification System EST Electronic Setting Tool ME Medium Expansion Retrievable Bridge Plug WIV Water Injection Valve MFCT...
Proceedings Papers

Paper presented at the Abu Dhabi International Petroleum Exhibition and Conference, November 10–13, 2014
Paper Number: SPE-171836-MS
...Figure 9 Ultrasonic (a), MFCT Logs (b) And Camera Images Of ICD #34 (c) ...
Proceedings Papers

Paper presented at the Abu Dhabi International Petroleum Exhibition & Conference, November 12–15, 2018
Paper Number: SPE-192947-MS
... caliper tool (MFCT) to supplement lab testing and modeling results. Most of these wells were reported to have ~25 to 300 ppm of H 2 S in the gas phase in addition to ~3.5% CO 2 . The chloride level in produced water was in the range of 25,000 to 110,000 ppm. As expected, MFCT data show very low corrosion...
Proceedings Papers

Paper presented at the SPE Norway One Day Seminar, April 18, 2018
Paper Number: SPE-191301-MS
... test. A 24 arm Multi Finger Caliper Tool (MFCT) was then used to map the condition of the wellbore. Upon receiving the results of the MFCT a suitable setting depth was identified 111ft above the Lock Mandrel fitted with the WIV. The client didn't want to attempt a recovery of the WIV assembly because...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 21–23, 2021
Paper Number: SPE-206221-MS
... measurement errors (respectively interpretation errors) are often insufficiently considered in the well integrity evaluation. There are basically two different options to measure casing wear: (1) Multi-finger caliper tool (MFCT) and (2) Acoustic caliper and wall thickness measurement tool. In the Culzean...
Proceedings Papers

Paper presented at the Abu Dhabi International Petroleum Exhibition & Conference, November 12–15, 2018
Paper Number: SPE-192836-MS
... caliper to evaluate internal tubing conditions. Results are in the table below: Well Name Well Drilled / WO Corrosion Tool Corrosion Log Date Results Years before log H2S (ppm) CO2 (ppm) Comments X0623 Mar-07 MFCT May-18 No corrosion 11 1,000 24,000 L80 completion...
Proceedings Papers

Paper presented at the SPE/ICoTA Coiled Tubing Roundtable, March 7–8, 2001
Paper Number: SPE-68417-MS
.... A number of tools on the market were capable of detecting corrosion inside and-or outside of tubulars. Examples are: Ultra Sonic Imaging Tool (USIT) Corrosion Evaluation Tool (CET) Multi Finger Caliper Tool (MFCT) All the above tools will give an indication where the corrosion has taken...
Proceedings Papers

Paper presented at the SPE/ICoTA Coiled Tubing Conference & Exhibition, April 4–5, 2006
Paper Number: SPE-99360-MS
... Crossflow: 650 bpd in upward direction Well Condition: Unknown Minimum ID: 3.75 in. ID through Ocre tool Rig Up Height: 59 ft Intervention Objective The intervention objectives were to run a multi finger caliper tool (MFCT) and production logging tool (PLT) on electric wireline...
Proceedings Papers

Paper presented at the The 27th International Ocean and Polar Engineering Conference, June 25–30, 2017
Paper Number: ISOPE-I-17-444
..., giving particular attention to the relation between geometry and wave reflection. Rezaei et al. (2013) presents a numerical investigation on the efficiency of a catamaran-type fixed breakwater under solitary waves using this MFCT-VOF model. A parametric study was undertaken on the main geometrical...

Product(s) added to cart

Close Modal