Surface-equipment schematic (<span class="search-highlight">MAWP</span> = maximum allowable working pressure).
Published: 01 May 1988
Fig. 4 Surface-equipment schematic (MAWP = maximum allowable working pressure). More
Images
A real case of WAT, PPT and <span class="search-highlight">MAWP</span> from the pipeline network for Benar feeder...
Published: 25 October 2020
Figure 3 A real case of WAT, PPT and MAWP from the pipeline network for Benar feeder line, (a) WAT and PPT, (b) MAWP and pump shutdown set pressure. More
Images
Design chart for pipe with 100bar Maximum Allowable Working Pressure (<span class="search-highlight">MAWP</span>)...
Published: 09 November 2020
Figure 7 Design chart for pipe with 100bar Maximum Allowable Working Pressure (MAWP) More
Journal Articles
J Pet Technol 60 (02): 69–70.
Paper Number: SPE-0208-0069-JPT
Published: 01 February 2008
..., Houston, 30 April-3 May. For many years, pipe-specification standards have required that piping downstream of the wellhead be adequate to sustain a full wellhead shut-in. This inherently safe design practice ensured that the flowline pipe was specified with a maximum allowable working pressure (MAWP...
Proceedings Papers

Paper presented at the PSIG Annual Meeting, April 16–19, 2013
Paper Number: PSIG-1314
... increased to 177,000 BOPD when Maximum Allowable Working Pressure (MAWP) reduced from 1463 psi to 950 psi. This paper shows how to increase flow rates without reaching MAWP, two methods are recommended: loop the existing pipeline using a 406.4 mm x 56 km pipe. Use a drag reducing agent (DRA) to reduce...
Proceedings Papers

Paper presented at the North Africa Technical Conference and Exhibition, April 15–17, 2013
Paper Number: SPE-164608-MS
... rate increased to 177,000 BOPD when maximum allowable working pressure (MAWP) reduced from 1463 psi to 950 psi. This paper shows how to increase flow rates without reaching MAWP, two methods are recommended: 1) loop the existing pipeline using a 406.4 mm x 56 km pipe. 2) Use a drag reducing agent (DRA...
Proceedings Papers

Paper presented at the CORROSION 2019, March 24–28, 2019
Paper Number: NACE-2019-12918
... Washington materials and corrosion Upstream Oil &amp; Gas Thickness texas 77084 wall thickness flowline corrosion riser corrosion inspection calculation ut inspection Houston operator inspection interval MAWP minimum wall thickness ultrasonic thickness Pipeline Corrosion well integrity gas...
Proceedings Papers

Paper presented at the Abu Dhabi International Petroleum Exhibition & Conference, November 15–18, 2021
Paper Number: SPE-207450-MS
... for design pressure as MAWP and accordingly adjust hydro test pressure followed by R-stamp requirements for rerating and repair. Shell side hydro test is restricted until recommendations are implemented Novel/Additive Information (25 - 75 words) Although conventional approach of replacing complete Shells...
Journal Articles
J Pet Technol 70 (09): 112–113.
Paper Number: SPE-0918-0112-JPT
Published: 01 September 2018
... a certain gel strength threshold) is still breakable by application of export pump pressure within the pipeline maximum allowable working pressure (MAWP). With a 20-in. pipeline, a radial temperature profile exists in which the center of the pipeline usually will have a higher temperature, making it easier...
Proceedings Papers

Paper presented at the SPE/IATMI Asia Pacific Oil & Gas Conference and Exhibition, October 17–19, 2017
Paper Number: SPE-186295-MS
... in the pipeline below its PP and still be breakable by applying pressure within the pipeline's Maximum Allowable Working Pressure (MAWP). Furthermore, the size of pipeline and the wax's natural insulation capability provides a radial temperature profile which can prevent the core pipeline from seeing a rapid...
Journal Articles
SPE Prod & Oper 23 (02): 280–286.
Paper Number: SPE-102524-PA
Published: 19 May 2008
... operational SOP. Enhanced annulus-pressure monitoring. All annulus pressures are entered daily into a database. Wells with annuli having pressures higher than MAWP or exhibit other indications of mechanical anomalies are reported to the well integrity engineers for further review. Regulatory agencies...
Proceedings Papers

Paper presented at the Offshore Technology Conference, May 6–9, 2002
Paper Number: OTC-14128-MS
... Abstract The Typhoon Field development required 9,000 psi MAWP flowlines from the four subsea wells to the TLP. An overview is presented of the design, manufacturing and installation of these four flexible flowlines. The flowline design required the use of insulation for flow assurance, start...
Journal Articles
J Pet Technol 59 (01): 64–66.
Paper Number: SPE-0107-0064-JPT
Published: 01 January 2007
... than the maximum- allowable working pressure (MAWP) or exhibiting other indications of mechan- ical anomalies are reported to the well- integrity engineers for further review. SOPs. Specific procedures and pro- cesses to ensure implementation of the Well Integrity System Policy require- ments...
Journal Articles
SPE Proj Fac & Const 4 (01): 1–7.
Paper Number: SPE-114141-PA
Published: 05 March 2009
... of the world. In many cases, the MAWP can be reduced in-line with reduced wellhead pressures for multiphase lines or reduced pump pressure requirements for oil transport lines. This can win back substantial pipeline wall thickness for use as additional "corrosion allowance" for future life prediction. Also...
Journal Articles
J Pet Technol 63 (12): 67–69.
Paper Number: SPE-1211-0067-JPT
Published: 01 December 2011
...- pressure tanks have a maximum allow- able working pressure (MAWP) of 0.5 to 15 psig, with OSHA requirements that are very similar to those for pressure ves- sels. Atmospheric tanks have an MAWP of 0 to 0.5 psig and must be used only for storage of crude petroleum. Specifying Rotating Equipment for Safety...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 24–27, 2006
Paper Number: SPE-102524-MS
..." is currently in draft. It provides calculation examples of Maximum Allowable Working Pressure (MAWP), the maximum allowable operating pressure on an annulus, and provides flowcharts illustrating potential actions when sustained casing pressure is discovered. Company Requirements BP has several internal...
Proceedings Papers

Paper presented at the The 32nd International Ocean and Polar Engineering Conference, June 5–10, 2022
Paper Number: ISOPE-I-22-134
... vessels and piping), the calculation methods can be used to find a reduced Maximum Allowable Working Pressure (MAWP), and this paper is focused in find this information. The section has 3 assessment procedures levels, as follows: Level 1 assessment This is a simplified technique that does not account...
Journal Articles
Oil & Gas Fac 1 (04): 38–46.
Paper Number: SPE-141974-PA
Published: 21 August 2012
.... In upstream oil and gas operations, there are two types of tanks according to OSHA: Low-pressure tanks maximum allowable working pressure (MAWP) from 0.5 to 15 psig 40 Oil and Gas Facilities August 2012 August 2012 Oil and Gas Facilities 41 Atmospheric tanks MAWP from 0.0 to 0.5 psig For low...
Proceedings Papers

Paper presented at the Offshore Technology Conference, April 30–May 3, 2007
Paper Number: OTC-18613-MS
... to sustain a full wellhead shut-in. This inherently safer design practice ensured that the flowline pipe was specified with a maximum allowable working pressure (MAWP) equal to or greater than the maximum pressure expected to be produced by the well. This practice has been proven to provide adequate...
Proceedings Papers

Publisher: Society of Petroleum Engineers (SPE)
Paper presented at the SPE/IADC International Drilling Conference and Exhibition, March 7–9, 2023
Paper Number: SPE-212545-MS
... to the casing run. Fig. 8 below is an excerpt of the landing string qualification summary page showing some of the critical components reviewed prior to this 16 in. run. However, because the shear pressure at the 16 in. liner hole section MAWP was calculated to be more than 90% of the BSR operating...