1-20 of 18420 Search Results for

Liquid meters

Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Proceedings Papers

Paper presented at the 3rd World Petroleum Congress, May 28–June 6, 1951
Paper Number: WPC-4811
... Synopsis Since there is no published work on the slippage characteristics of positive displacement liquid meters and, since such information is needed by meter operators, the author has undertaken a special meter testing project at East Chicago to furnish information. He describes...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, October 3–6, 1999
Paper Number: SPE-56584-MS
... Abstract The Pressure-Pulse multiphase metering method is described. The combined effects of water-hammer and speed of sound in gas-liquid mixtures are used to measure the mass flow rate. Through continuity the mass flow rate at the wellhead is the same as the mass flow rate downhole...
Proceedings Papers

Paper presented at the Abu Dhabi International Petroleum Exhibition & Conference, November 15–18, 2021
Paper Number: SPE-207674-MS
...%. For some wells inaccuracy of MPFM liquid rate measurement could reach 30-50%. The main goal of this research was to improve the accuracy of multiphase flow meter production rate measurements. Methods, Procedures, Process: More than 80 oil production wells were involved in the research, more than 100...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 26–29, 1982
Paper Number: SPE-11165-MS
... considering that the injection medium initially would not be available as a by product of production. Preliminary data compiled from a study to perform automated volumetric metering and injection rate control of CO2, using the liquid turbine meter is presented in this treatise. Observations of CO2 flow within...
Proceedings Papers

Publisher: BHR Group
Paper presented at the 18th International Conference on Multiphase Production Technology, June 7–9, 2017
Paper Number: BHR-2017-413
... ABSTRACT A very simple, low-cost gas-liquid flow meter that only employs conventional field instrumentation has been used to monitor severe slugging occurring at the exit of a vertical pipe. This meter was originally developed for conventional oil field applications [1] and is based...
Journal Articles
J Pet Technol 66 (11): 139–142.
Paper Number: SPE-1114-0139-JPT
Published: 01 November 2014
...Chris Carpenter This article, written by JPT Technology Editor Chris Carpenter, contains highlights of paper SPE 166652, ’Use of Sonar Metering To Optimize Production in Liquid-Loading-Prone Gas Wells,’ by C.A. Shields and M. Dollard, Marathon Oil UK, and S. Sridhar, G. Dragnea, and M. Illingsworth...
Journal Articles
SPE Res Eval & Eng 17 (04): 449–456.
Paper Number: SPE-170253-PA
Published: 31 July 2014
... by the separator made possible the identification of some carry-over in the separator at a high choke setting. When the choke size was increased, the separator gas rate increased, whereas the liquid rate dropped at the separator, resulting in a very low condensate/gas ratio (CGR). The multiphase meter...
Proceedings Papers

Paper presented at the OTC Brasil, October 29–31, 2013
Paper Number: OTC-24395-MS
... entire test production control gas rate flow rate separator retention time cleanup period well offshore brazil flow period rate measurement choke size drillstem testing flow metering liquid rate upstream oil & gas main flow period mass rate production monitoring condensate...
Proceedings Papers

Paper presented at the SPE Offshore Europe Oil and Gas Conference and Exhibition, September 3–6, 2013
Paper Number: SPE-166652-MS
...). There are currently 12 producing gas wells; varying water-gas ratios and low gas rates result in liquid loading being a major flow assurance issue. This paper discusses the use of clamp-on sonar flow meters to minimize losses associated with well testing and the subsequent benefits that were seen with respect...
Proceedings Papers

Paper presented at the Canadian Unconventional Resources and International Petroleum Conference, October 19–21, 2010
Paper Number: SPE-138978-MS
... was supported through research in wet-gas metering conducted by Edward Wichert in the 1970's. The research findings of Mr. Wichert determined the accuracy and reliability of orifice meters to measure wet-gas. The basis of the research included effects of a liquid upon gas measurement and the determination...
Proceedings Papers

Publisher: BHR Group
Paper presented at the 13th International Conference on Multiphase Production Technology, June 13–15, 2007
Paper Number: BHR-2007-E2
... INTRODUCTION The flow meter presented in this paper is based on the isokinetic sampling of the gas-liquid mixture, followed by separation and metering of the individual phases. With respect to other MPFMs, the main feature of the meter is the advantage of self-calibration, [1], [2]. Moreover...
Proceedings Papers

Paper presented at the SPE Production Operations Symposium, April 2–4, 1995
Paper Number: SPE-29490-MS
... Abstract A field example of debris-ridden liquids in an orifice meter is presented in this paper. Flow conditions in gas pipelines containing hydrocarbon liquids and particulate matter are discussed. Known effects on measurement of the presence of these materials in orifice meters is presented...
Journal Articles
J Pet Technol 17 (06): 657–660.
Paper Number: SPE-1064-PA
Published: 01 June 1965
... to obtain flow rates with an orifice meter for homogeneous fluids such as air, natural gas, various industrial gases, steam. water, oil and all liquids whose physical properties are known. However, serious errors in measurement result when this simple device is used where two or more fluid phases comprise...
Images
Images
Production rate increase detected by <span class="search-highlight">liquid</span> phase probe and gas <span class="search-highlight">meters</span>.
Published: 30 September 2001
Figure 9 Production rate increase detected by liquid phase probe and gas meters. More
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 21–24, 2008
Paper Number: SPE-116460-MS
... of the main parameters impacting the PSS performance and liquid metering accuracy. It was observed that the variation in the diluent percentage impacted the liquid metering by over- or under-estimating the total liquid measurement. High viscosities and foamy mixture effects were countered by making minor...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, October 4–7, 1992
Paper Number: SPE-24806-MS
... separators direct oil, water, and gas streams to single phase meters. The motive force to push the liquid and gas streams through metering devices is supplied by separator (ie well stream) pressure. Test systems for multi-well service must have separators and meters large enough to handle the highest...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 24–27, 2006
Paper Number: SPE-103087-MS
... bypass valving, coriolis liquid meter, infrared water-cut meter, vortex shedding gas meter and a data acquisition unit. One key finding is that separation is not needed in many such applications, thereby significantly reducing the size, weight and cost of future testers. This is due to the inherent...
Journal Articles
J Pet Technol 48 (02): 150–153.
Paper Number: SPE-27590-JPT
Published: 01 February 1996
... with quality steam is part of the injectant. Projects that are run with all hot water or all superheated vapor, both easily distributed and metered, have usually performed poorly by comparison. Two major problems arise with quality steam. First, distributing the liquid and vapor phases through a large piping...
Proceedings Papers

Paper presented at the International Petroleum Technology Conference, January 13–15, 2020
Paper Number: IPTC-19799-Abstract
... consists of electrical ICVs, downhole liquid metering and WC and pressure measurements sensors. The unique smart completion allows real-time optimization and controlling of unwanted fluids on the segment level, utilizing the fast electrical ICVs. A comprehensive methodology has been developed...

Product(s) added to cart

Close Modal