J Pet Technol 14 (10): 1087–1090.
Paper Number: SPE-343-PA
Published: 01 October 1962
... lease automatic custody transfer unit is its ability to accurately measure and test the liquid passing through it. A large percentage of the LACT units now in service use positive displacement meters as measuring media. It is with these meters that this paper is primarily concerned. Meters have proved...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 26–29, 1982
Paper Number: SPE-11112-MS
... a master meter is utilized to prove a LACT meter, it must be calibrated to determine a meter factor utilizing the same flow rate and viscosity product which is expected at the field facility. The meter factor is obtained for the master meter by comparing the volume throughput registered on teh totalizer...
Proceedings Papers

Paper presented at the Fall Meeting of the Society of Petroleum Engineers of AIME, October 4–7, 1959
Paper Number: SPE-1316-G
..., the oil production departments of 'Various oil companies have devised References and illustrations at end of paper 2 FIELD EXPERIENCE WITH LACT. UNITS :&tUIPPED WITH PD MEI'ERS B16-G was the first method to receive practical acceptance. Positive displacement meter units have now also gained acceptance...
Proceedings Papers

Paper presented at the SPE Production Automation Symposium, May 17–18, 1962
Paper Number: SPE-346-MS
... components can be related to the entire system. OPERATIONAL SEQUENCE - DUMP TANK TYPE LACT SYSTEM A flow diagram of the LACT unit is shown in Fig. 1 and the operational se~uence is as follows. As a starting point it is assumed that the meter tank is, empty and that the level in the surge tank is at Levell...
Proceedings Papers

Paper presented at the Offshore Technology Conference, August 16–19, 2021
Paper Number: OTC-30926-MS
... on the Coriolis Meters that are used in the LACT units at two different field sites. They were pulling the meter out every month (in some instances within 3 weeks) to clean the meter and have it proved again, due to extensive fouling along the walls of the Coriolis meter tubes. The meter sees flows in the range...
Proceedings Papers

Paper presented at the Abu Dhabi International Petroleum Exhibition & Conference, November 15–18, 2021
Paper Number: SPE-207674-MS
... by means of multiphase flow meter and that measured by means of lease automatic custody transfer (LACT) unit exceeding 5% (Formula 1), which amounts in absolute figures to 20,000 oil barrels a day, where more than a half of all the wells revealed production rate measurement error reaching up to 30-50...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 16–19, 1984
Paper Number: SPE-13020-MS
... to further assure stable gas-free liquid. Continuous on-line sensors will monitor water content, temperature, pressure, and flow rate, and will alarm when operating conditions exceed preset 1 imi ts. Automatic diversion or shutdown to prevent shipping oil not meeting measurement standards will be provided...
Proceedings Papers

Paper presented at the SPE Western Regional Meeting, March 23–25, 1994
Paper Number: SPE-27865-MS
... available for review. Even with a sophisticated data collection system, interpretation of field results continues to be the single most difficult issue in confirming a reliability of the various probes. Though flow meters can be checked against a tank or a LACT prover, instantaneous full stream water cuts...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 30–October 3, 2001
Paper Number: SPE-71477-MS
... three components are the same to within ±2%. Next the fluid passes through a Momentum meter. Which comprises of a set of dual-venturies configured to provides the distinction between liquid and gas flow. Gas moves with a relatively higher velocity when compared to liquids through a restriction...
Proceedings Papers

Paper presented at the SPE Production Automation Symposium, May 17–18, 1962
Paper Number: SPE-347-MS
... pools shall also apply if more than one zone or pool is involved. Measuring facilities for the transfer of liquid hydrocarbons from individual leases to a central marketing facility [tank battery of LACT unit] shall provide adequate means for net volume determination and fail-safe operation. The over...
Journal Articles
SPE Prod & Oper 3 (04): 633–636.
Paper Number: SPE-15394-PA
Published: 01 November 1988
... before sales through a LACT meter. Allocation factors, defined as the ratio of net LACT unit oil sales volume to the sum of BS&W-corrected well production measured at the individual well separators, are then computed for each battery. In the original installation, the oil stream from...
Journal Articles
SPE Prod & Oper 22 (01): 41–45.
Paper Number: SPE-88903-PA
Published: 20 February 2007
... that the linearity functions used by existing modern flow computers do not recognize calibration errors, nor do they ensure minimum weighted residuals of the system meter factors. The effect of incorrect meter linearity functions is apparent in lease automatic custody transfer (LACT) units equipped with flowmeters...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 27–30, 1998
Paper Number: SPE-49062-MS
... and the operating envelope of the shipping system. The dry oil shipping system consists of a Dry Oil T* three (3) LACT Charge Pumps (can type pumps), three (3) LACT units for metering and sampling of basic sediment and water (BS&W) and three (3) horizontal multi-stage centrifugal 267 4 M. A. CUROLE AND A. J. TURLEY...
Proceedings Papers

Paper presented at the Abu Dhabi International Petroleum Exhibition & Conference, November 9–12, 2020
Paper Number: SPE-203321-MS
... of increased cash flow to the company, an evaluation of the existing Lease Automatic Custody Transfer (LACT) Oil and Gas Sales measurement equipment and infrastructure was needed to determine equipment accuracy, throughput capability, and obsolescence. This was to ensure the equipment used can measure...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 22–26, 1985
Paper Number: SPE-14358-MS
... drillstem/well testing injection psig upstream oil & gas powell pressure maintenance unit condensate reservoir SPE Society of Petroleum Engineers SPE 14358 Powell Pressure Maintenance Unit Enhanced Recovery Project That Is Providing Liquid Sales in a Limited Gas Market Environment by L.B. Heath...
Journal Articles
SPE Prod & Oper 16 (01): 9–13.
Paper Number: SPE-69199-PA
Published: 01 February 2001
... the system curve, pump curves then could be plotted to determine pipeline pumps’ capacities and the operating envelope of the shipping system. The dry-oil shipping system consists of a dry-oil tank, three LACT charge pumps ("can" type pumps), three LACT units for metering and sampling of basic sediment...
Journal Articles
J Pet Technol 25 (12): 1425–1431.
Paper Number: SPE-4701-PA
Published: 01 December 1973
..., and then later were served by only one LACT unit and one tank battery with one tank and two treaters. Positive-displacement meters are used to measure liquid volume, and capacitance probes are used to indicate the percentage of water in the effluent stream. LACT facilities use these for measuring BS&W. The same...
Journal Articles
J Pet Technol 19 (12): 1527–1530.
Paper Number: SPE-1924-PA
Published: 01 December 1967
... liberation, and adjusting the amount of valve movement permits regulation of flow rate. Correction of temperature to standard conditions can be accomplished with an automatic temperature compen- sator on the positive displacement liquid meter. An error is thus introduced as water content of the emulsion...
Journal Articles
SPE Prod & Oper 9 (03): 183–187.
Paper Number: SPE-26396-PA
Published: 01 August 1994
... was introduced into an oil-skimming pit of the lease automatic custody transfer (LACT) Unit 10 at the Salt Creek field in Wyoming. Field produced water enters this pit from the oil/water separation treatment train at an average flow rate of 5,000 B/D with a potential maximum of 98,000 B/D. Water conditions...
Proceedings Papers

Paper presented at the SPE Annual Caspian Technical Conference, October 16–18, 2019
Paper Number: SPE-198394-MS
... was introduced in TCO (Tengizchevroil) in 2016 to clean-up new wells prior to performing a Plant flowback. The MRM unit utilizes an EverGreen Burner that performs fallout free and smokeless combustion of liquid hydrocarbons and residual well materials during well clean-ups. Cleaning-up new wells using the MRM...

Product(s) added to cart

Close Modal