1-20 of 625 Search Results for

Inhibitor truck

Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 23–26, 1979
Paper Number: SPE-8414-MS
... was by truck at each individual well. Wright and Kepley reported ten years ago on a method of using a corrosion inhibitor-biocide by truck. This method is much more expensive by modern day standards and foaming of the chemical mixture was at times a problem to the storage field operations although problem...
Proceedings Papers

Paper presented at the CORROSION 2008, March 16–20, 2008
Paper Number: NACE-08153
... of deaeration. Keywords: ethanol, pipelines, stress-corrosion cracking, inhibitors, oxygen scavengers, deaeration INTRODUCTION Currently, FGE is transported primarily by railroad tanker cars, tanker trucks, and barges. SCC has been observed in carbon steels in contact with FGE in user terminals, storage tanks...
Proceedings Papers

Paper presented at the SPE International Oilfield Corrosion Conference and Exhibition, May 12–13, 2014
Paper Number: SPE-169632-MS
... artificial lift design and installation of new tubing, new pumps following API standards, corrosion inhibitor injection, dosing skids and optimization of production parameters. At the same time Corrosion Monitoring Devices (DMC) were installed in 10% of injection points. Appropriate chemical trucks...
Proceedings Papers

Paper presented at the CORROSION 2017, March 26–30, 2017
Paper Number: NACE-2017-9450
... when there are dedicated trucks to distribute the chemical under conditions of high pressure.8 The application of these corrosion inhibitors to the prevention of corrosion in varied conditions is described. In some instances the use of these inhibitors has been 1 Paper No. 9450 ©2017 by NACE...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 26–28, 2016
Paper Number: SPE-181735-MS
... halite scale asphaltene inhibition concentration spe international symposium hydrate inhibition fracturing fluid remediation of hydrates inhibitor Chemical Delivery System halite inhibitor wellbore halite formation society of petroleum engineers international symposium the woodlands...
Proceedings Papers

Paper presented at the SPE Middle East Oil and Gas Show and Conference, March 18–21, 2019
Paper Number: SPE-194893-MS
... involves bullheading a corrosion inhibitor batch treatment. However, high costs and low effectiveness are driving a shift from batch treatments to continuous downhole treatment techniques. This paper describes the process of converting to continuous downhole treatments. Methods, Procedures, Process...
Proceedings Papers

Paper presented at the CORROSION 2003, March 16–20, 2003
Paper Number: NACE-03331
... of the relationships established by NACE and API. Current corrosion treatments on the mechanical pumping wells consist of batch treatments using a dedicated treater truck or continuous injection via casing using a side stream flush. The frequency of batch treatments, the amount of inhibitor used and the flush volume...
Proceedings Papers

Paper presented at the SPE Russian Oil and Gas Technical Conference and Exhibition, October 28–30, 2008
Paper Number: SPE-117381-MS
... to push the batching pig into the expansion chamber. Steam truck shall be used to open the gate valve in winter time. 3.6 Assemble injection line to inject corrosion inhibitor. 3.7 Hook up the injection line to the air-valve on the launching facility. 3.8 Pressure test injection line...
Journal Articles
J Pet Technol 28 (06): 624–628.
Paper Number: SPE-5612-PA
Published: 01 June 1976
.... Successful corrosion control programs using these treating methods are expensive, since they usually require a truck-mounted pump and operator in addition to the inhibitor. Schedules for such programs are frequently difficult to maintain, resulting in treatment inconsistency. It is also difficult to optimize...
Proceedings Papers

Paper presented at the CORROSION 2020, June 14–18, 2020
Paper Number: NACE-2020-14686
... or wax inhibitors is automatically adjusted to maintain a predetermined concentration of the chemical in response to a variation of the rate of water production in the well. Scale-model test results and real-time simulations of system operation are presented. The stationary bed of solids formed...
Proceedings Papers

Paper presented at the SPE Western Regional/AAPG Pacific Section Joint Meeting, May 19–24, 2003
Paper Number: SPE-83481-MS
... every two weeks using two or three gallons of binary corrosion inhibitor by batch treatment via treater truck. Overflush varies by well, depending upon the static pumping level. Results were impressive. For the four years just previous to using a binary corrosion inhibitor, downhole rod/pump repairs...
Proceedings Papers

Paper presented at the International Petroleum Technology Conference, November 14–16, 2016
Paper Number: IPTC-18840-MS
... are transported to the injection site by trucks and supply vessels. Moreover, CO 2 impact study was conducted, and it is found that we can manage the potential risks related to corrosion and scale formation by using suitable countermeasure such as CRA's and inhibitors. Finally, based on the result of corrosion...
Proceedings Papers

Paper presented at the International Petroleum Technology Conference, December 6–9, 2015
Paper Number: IPTC-18270-MS
... Abstract To avoid hydrate formation, Kinetic Hydrate Inhibitor (KHI) is injected into the upstream wet gas pipelines. KHI eventually remains in the produced water which is treated for H2S and oil removal before it is re-injected into deep disposal wells. Industry regulators in the State...
Proceedings Papers

Paper presented at the CORROSION 2010, March 14–18, 2010
Paper Number: NACE-10075
..., and methanol. Recently, it has been found that the use of inhibitors is promising in order to inhibit SCC (6). It has been shown in general that if the corrosion potential of carbon steel in FGE is higher than 100 mV vs. Ag/AgCl (with 1 M LiCl in EtOH) carbon steel is susceptible to SCC. Corrosion...
Proceedings Papers

Paper presented at the CORROSION 2008, March 16–20, 2008
Paper Number: NACE-08369
... to protect galvanized and steel surfaces. After two years operation, galvanized tubes and mild steel in systems show outstanding corrosion protection, control of ?white rust? and no scale at TDS up to 150,000 in tower water. New technology that produces inhibitor chemistry from source water silica permits...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, October 30–November 2, 2011
Paper Number: SPE-145454-MS
... Round Trip to Disposal 300 mi Trucking Transport Cost per Hour $ 95 /hour Equivalent Cost per Barrel $ 5.07 /bbl Disposal / Injection Cost $ 1.00 /bbl The model assumes both biocide and scale inhibitor are fully replaced by the process. We assumed a 10% increase in effectiveness...
Proceedings Papers

Paper presented at the CORROSION 98, March 22–27, 1998
Paper Number: NACE-98281
... other month. In addition, some of the water tanks were batch treated with a scale inhibitor to protect the turbine meters located on the discharge side of the water pumps. The transportation and disposal of current and anticipated produced water is an important issue in the San Juan Basin. Cox...
Proceedings Papers

Paper presented at the 3rd World Petroleum Congress, May 28–June 6, 1951
Paper Number: WPC-4708
..., tankers, tank trucks, pipe lines, meters, and pumps. Corrosion of customers equip- ment though not the responsibility o the petro- leum industry can be controlled with the same prod- uct-soluble inhibitor used to protect refinery-owned equipment, and only one blending operation is required. This product...
Journal Articles
J Pet Technol 40 (09): 1123–1126.
Paper Number: SPE-18459-PA
Published: 01 September 1988
... are the inevitable results ofpumping trucked water or pit water into an injection system. Improperlyselected corrosion inhibitors that are not sufficiently soluble in theinjection water can contribute to plugging. In addition, contaminants may inadvertently enter the system. One of theprimary problems in most...
Journal Articles
J Pet Technol 14 (03): 257–260.
Paper Number: SPE-115-PA
Published: 01 March 1962
... of oilwell casing, including cathodic protection, casing coatings, full-string cementing and inhibitors. In particular, cathodic protection has been widely used with apparently good results. However, there is a definite need for a method of periodically measuring the extent of external casing damage...

Product(s) added to cart

Close Modal