SPE Prod & Oper 6 (02): 161–165.
Paper Number: SPE-19076-PA
Published: 01 May 1991
...V.C. Ting; L.L. Schexnayder; D.B. Conkling Summary This paper presents the design criteria, performance characteristics, andcalibration procedures relating to a turbine-meter flow-calibration facilityused in the high-volume custody transfer of natural gas. The facility, locatedin Venice, LA...
Proceedings Papers

Paper presented at the Offshore Technology Conference, April 30–May 3, 2001
Paper Number: OTC-13148-MS
... involved the the testing in wet gas of a 6- inch turbine meter in liquid loadings of up to 2% by mass at a pressure of 60 barg and pipe Reynolds numbers from 1 to 9 million. The maximum shift in the turbine meter factor found due to the presence of the kerosene was -0.75% at a Reynolds number of 2.7...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 23–26, 1990
Paper Number: SPE-20644-MS
... Arch Telemetry system is a SCADA system consisting of solar powered remote terminal units (RTU's) at each gas well, UHF radio communications and a host computer located in the field production office. The gas turbine meters, used at each well for production allocation measurement, are considered part...
Proceedings Papers

Paper presented at the SPE Gas Technology Symposium, January 22–24, 1991
Paper Number: SPE-21510-MS
... different gas flow measurement systems when installed in series in a metering run by measuring the flow of compressed air at variable rates from 35 to 905 mscf/d. The flow meters tested consisted of two gas turbine meters and two standard orifice plate meters which were connected to various data recording...
Proceedings Papers

Paper presented at the SPE Nigeria Annual International Conference and Exhibition, August 5–7, 2014
Paper Number: SPE-172444-MS
... Scientists and Engineers went to work and came up with volumetric measures (e.g. gas turbine meters) that can operate at such high pressures that obtain in gas flow systems. These measures are more accurate and can be revalidated online with ease. Modern measurement technologies have further...
Journal Articles
SPE Prod & Oper 6 (04): 454–458.
Paper Number: SPE-19767-PA
Published: 01 November 1991
... to move gas through acalibrated section of known volume. It is constructed to perform on-sitecalibration of such flowmeters as gas turbine or orifice perform on-sitecalibration of such flowmeters as gas turbine or orifice meters at operatingconditions. The unit can easily be set up in series with a field...
Proceedings Papers

Paper presented at the Offshore Technology Conference Asia, March 22–25, 2016
Paper Number: OTC-26594-MS
... is metered through a choice of three gas turbine meters according to the flowrate required. The calibrated ranges of these flowmeters are: The gas flowrate is measured at the gas supply pressure (typically 17 bar). However, by operating the test section at reduced pressures it is possible to cover the full...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 24–27, 2006
Paper Number: SPE-102962-MS
... allocation. These errors distort the reservoir engineer production information and directly affect the fiscal allocation from multiple owners. A SONAR-based system to measure the gas void fraction (GVF) next to turbine and Coriolis meters is proposed as a method to correct for gas bubbles. A test...
Proceedings Papers

Paper presented at the PSIG Annual Meeting, May 24–27, 2011
Paper Number: PSIG-1107
... in the compressions stations making use of the available data at pipeline control room. The basic idea is to take advantage of the correlation that exists for fuel flow rate to air inlet temperature and axial compressor speed of the turbine. This approach is applied in two-shaft gas turbines where the gas producer...
Proceedings Papers

Paper presented at the SPE Russian Petroleum Technology Conference, October 15–17, 2018
Paper Number: SPE-191747-18RPTC-MS
... artificial lift system production logging inductive flowmeter flow rate production monitoring Upstream Oil & Gas Efficiency Reservoir Surveillance accuracy thermomanometric system group installation application reliability operation sensor installation Turbine Flowmeter...
Proceedings Papers

Paper presented at the Offshore Technology Conference Asia, March 22–25, 2016
Paper Number: OTC-26828-MS
... turbine meters, with the following calibrated ranges: The water is metered using flat-blade turbine meters with the following calibrated ranges: The nitrogen is metered through a choice of three gas turbine meters according to the flow rate required. The calibrated ranges of these flow meters are: Figure...
Proceedings Papers

Paper presented at the Offshore Technology Conference, August 16–19, 2021
Paper Number: OTC-30926-MS
... for these nano surface treatments and the different application methods available for treating devices. Data will showcase the performance of nano surface treatments in common applications, such as Coriolis meters, turbine meters, valves, flow and level devices. Producers have seen significant extension...
Proceedings Papers

Paper presented at the Offshore Technology Conference, May 2–5, 2016
Paper Number: OTC-26898-MS
... not affect the system. This will enable the IPP turbines operate at the maximum installed capacity Figure 3 Modified system block diagram with trunk lines OTC-26898-MS 7 4. The use of Prepaid metering guarantees the revenue of the IPPs and this also guarantees the payment for the Gas companies and also...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 26–29, 1982
Paper Number: SPE-11165-MS
... considering that the injection medium initially would not be available as a by product of production. Preliminary data compiled from a study to perform automated volumetric metering and injection rate control of CO2, using the liquid turbine meter is presented in this treatise. Observations of CO2 flow within...
Proceedings Papers

Paper presented at the PSIG Annual Meeting, October 23–25, 2002
Paper Number: PSIG-0201
... of the seven gas-driven turbines hp was obtained directly from the installed torque meters. This provided a direct measurement of horsepower output and is the preferred method. For units without torque meters the gas horsepower was calculated utilizing unit pressures, flows, gas temperatures and other factors...
Proceedings Papers

Paper presented at the 9th World Petroleum Congress, May 11–16, 1975
Paper Number: WPC-16336
.... Gross oil measurements are handled by posi- tive displacement meters, gas measurements are handled by gas flow computers and water measure- ments are handled by turbine meters. Net oil measure- ments are determined from manual entry of sample information from a proportional sample. Positive displacement...
Proceedings Papers

Paper presented at the PSIG Annual Meeting, October 15–17, 2003
Paper Number: PSIG-0308
...]. The expected growth by 2020 in power generation capacity is 400,000 megawatts, of which 92% of this new growth load is expected to be serviced by gas-fired turbines. Gas consumption for power generation is predicted to grow from 6 TCF (~ 170,000 million cubic meters) to 17.4 TCF (~ 493,000 million cubic meters...
Proceedings Papers

Paper presented at the Drilling and Production Practice, January 1, 1964
Paper Number: API-64-164
...-displacement meters, turbine-type velocity meters, computing orifice meters, and momentum-mass meters are discussed and summaries of test results presented. Accessory instrumentation for direct readout, remote readout, and other purposes is described. INTRODUCTION Efforts in developing better gas...
Proceedings Papers

Paper presented at the Abu Dhabi International Petroleum Exhibition & Conference, November 7–10, 2016
Paper Number: SPE-183080-MS
... have not occurred had the PSU drainage system was properly designed and executed. Also, the extent of settlement would not have been significant, had there been no interconnection of oily and storm drain system. Monitoring systems included installing of crack meter between Gas Turbine foundation...
Proceedings Papers

Paper presented at the SPE Middle East Regional Meeting, March 27–29, 1961
Paper Number: SPE-77-MS
... operated ~tisfaotory with an acouracy of better than 1.0% but had a limited life . . due to over-speeding and oil and gas two-phase flow conditions. Turbine Meters - Turbine-Tw The 2t" turbine type meter without visoosi ty oompensation was installed in Abqaiq Gas Oil Separating Plant No.2 in a line from...