1-20 of 7131 Search Results for

Cement slurry design

Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Proceedings Papers

Paper presented at the International Petroleum Technology Conference, February 21–23, 2022
Paper Number: IPTC-21955-MS
.... The last 8 1/2-in. interval is drilled through the main pay zones in the Kareem, Rudeis, Cenomanian and Nubia formations followed by the 7-in. liner casing and cementing operations. The cement program was designed as a lead and tail slurry with properties to achieve optimum cement placement...
Journal Articles
SPE Drill & Compl 24 (03): 373–377.
Paper Number: SPE-113631-PA
Published: 27 September 2009
..., hydrocarbons could increase the temperature of the surrounding formation. These factors could destabilize the hydrates. Cement slurries are designed to lower the heat of hydration while meeting or exceeding the other properties needed for successful deepwater cementing. Heat of hydration is reduced by a factor...
Proceedings Papers

Paper presented at the SPE Russian Oil and Gas Technical Conference and Exhibition, October 28–30, 2008
Paper Number: SPE-114773-MS
... on compressive strength development. The optimization of slurry design takes all of these parameters into consideration while resolving the problem of heat insulation, thus helping reduce the chance of primary cementing failure over the life cycle of the well. The optimization of the cement slurry design makes...
Proceedings Papers

Paper presented at the SPE Indian Oil and Gas Technical Conference and Exhibition, March 4–6, 2008
Paper Number: SPE-113631-MS
... increase the temperature of the surrounding formation. These factors could destabilize the hydrates. Cement slurries are designed to lower the heat of hydration while meeting or exceeding the other properties needed for successful deepwater cementing. Heat of hydration is reduced by a factor of more than...
Proceedings Papers

Paper presented at the SPE Latin American and Caribbean Petroleum Engineering Conference, April 27–30, 2003
Paper Number: SPE-80999-MS
... ). Frigaard I.A. , Allouche M. & Gabard C. , Setting rheological targets for chemical solutions in mud removal and cement slurry design . Journal of Petroleum Technology , August ( 2001 ). Frigaard I.A. , Leimgruber S. & Scherzer O. , Variational methods and maximal...
Journal Articles
J Pet Technol 53 (08): 65–66.
Paper Number: SPE-0801-0065-JPT
Published: 01 August 2001
...Dennis Denney This article is a synopsis of paper SPE 64998, "Setting Rheological Targets for Chemical Solutions in Mud Removal and Cement-Slurry Design," by I.A. Frigaard, SPE, U. of British Columbia; M. Allouche, SPE, Schlumberger; and C. Gabard- Cuoq, SPE, U. Pierre et Marie Curie...
Proceedings Papers

Paper presented at the SPE International Symposium on Oilfield Chemistry, February 13–16, 2001
Paper Number: SPE-64998-MS
... and surprising, being in many respects counter to accepted oilfield intuition. The direct application of these results is in the design of spacer and cement slurry properties for effective mud removal during primary cementing. The breakdown of zonal isolation can sometimes be attributed to poor bonding...
Journal Articles
J Pet Technol 49 (08): 844–845.
Paper Number: SPE-0897-0844-JPT
Published: 01 August 1997
...William J. Pike This article is a synopsis of paper SPE 36973, "New Technology Improves Cement Slurry Design," by J.W. Anderson, SPE, A.I. Buchanan, SPE, and A. Susanto, P.T. BJ Services Indonesiaoriginally presented at the 1996 SPE Asia Pacific Oil and Gas Conference held in Adelaide, Australia...
Proceedings Papers

Paper presented at the SPE Asia Pacific Oil and Gas Conference, October 28–31, 1996
Paper Number: SPE-36973-MS
... in Indonesia are now benefiting from this new technology. Slurries are mixed and tested to ensure they meet design specifications well before they are required on site. The "Base Slurry" or "Liquid Cement Premix", which typically has a density of 16.0 pounds per gallon (ppg), is transported to the rig, diluted...
Journal Articles
SPE Comp App 5 (01): 21–25.
Paper Number: SPE-24417-PA
Published: 01 February 1993
...D. S. Kulakofsky; F-L. Wu; D. D. Onan; J. B. Wohleb Summary Traditionally, quality oilfield cement slurries have been based on rules of thumb and years of experience. The designs used in specific areas often were developed many years ago. Although these slurries may have used the best technology...
Proceedings Papers

Paper presented at the SPE Western Regional Meeting, March 30–April 1, 1992
Paper Number: SPE-24048-MS
... normal drilling operations provides essential information needed when designing cement slurries for critical primary cement jobs. The temperature memory recorder can be tripped into the well with pipe or wireline and can be dropped down the drillstring or tubing. Retrieving can be accomplished...
Book Chapter
Book: Cementing
Publisher: Society of Petroleum Engineers
Published: 01 January 1989
DOI: 10.2118/9781555630065-04
EISBN: 978-1-61399-916-5
Images
The new <span class="search-highlight">Cement</span> <span class="search-highlight">Slurry</span> <span class="search-highlight">Design</span> – Lead <span class="search-highlight">Slurry</span>
Published: 20 July 2020
Figure 12 The new Cement Slurry Design – Lead Slurry More
Images
High temperature <span class="search-highlight">cement</span> <span class="search-highlight">slurry</span> <span class="search-highlight">design</span> (mixed at 16.0 ppg) being returned to...
Published: 01 November 2010
Fig. 4 High temperature cement slurry design (mixed at 16.0 ppg) being returned to surface after being pumped around casing. More
Images
Consistency curve of 1.92 SG innovative <span class="search-highlight">cement</span> <span class="search-highlight">slurry</span> <span class="search-highlight">design</span> at 90 Deg C. (...
Published: 04 April 2017
Figure No. 5 Consistency curve of 1.92 SG innovative cement slurry design at 90 Deg C. (Field implemented in well # TVAU) More
Images
Proceedings Papers

Paper presented at the SPE Nigeria Annual International Conference and Exhibition, August 6–8, 2018
Paper Number: SPE-193469-MS
... has shown remarkable success. LCL cement additive is a liquid additive designed to lower equivalent circulating density (ECD) and impart excellent fluid-loss control, high-temperature suspension properties, and acid resistance to cement slurries. This paper summarizes the operational and logistical...
Proceedings Papers

Paper presented at the International Oil and Gas Conference and Exhibition in China, June 8–10, 2010
Paper Number: SPE-130266-MS
... and regulations of environmental requirement, but also contributes to environmental protection. The deepwater cement slurry, designed by using the DWC cement, environmentally friendly additives and micropheres, presents high early strength under low temperature, right-angle-set, short transition time of static...
Proceedings Papers

Paper presented at the The 32nd International Ocean and Polar Engineering Conference, June 5–10, 2022
Paper Number: ISOPE-I-22-094
... ABSTRACT Gas hydrate dissociation would damage the cementing quality seriously due to the hydration exothermic of cement slurry. Therefore, the well cement slurry with low hydration exothermic is necessary. The design of well cement slurry with low hydration heat mainly includes three steps...
Proceedings Papers

Paper presented at the Offshore Technology Conference, May 2–5, 2022
Paper Number: OTC-31699-MS
... identified that TOC has not covered the depleted sand ( Gorman 2021 ). The cement job has been pumped as per the designed parameters, adding conventional fibers into the cement slurry and minimizing the displacement rates as simulated by cement job modeling software to decrease the risk of losses. However...

Product(s) added to cart

Close Modal