1-20 of 291 Search Results for

Alternate PCP system configurations

Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 21–23, 2021
Paper Number: SPE-206228-MS
... was a 2.75" OD system configured with cup seals for 3-1/2" 9.2ppf tubing. Figure # 5 shows a diagram of the inflatable packer I-PCP anchoring device utilized in this application. The sucker-rod string was retrieved from the well in order to enable deployment of the insertable pumping BHA within the 3.5...
Proceedings Papers

Paper presented at the SPE Asia Pacific Oil and Gas Conference and Exhibition, October 23–25, 2018
Paper Number: SPE-192043-MS
... packer I-PCP anchoring device is configured with specific shear-pinned settings to prevent premature activation during deployment. Figure # 1 shows the device and its main components, which function as follows: a) the hydraulically activated slips are the system's main anchor, b) the upper inflatable...
Proceedings Papers

Paper presented at the SPE Heavy Oil Conference-Canada, June 11–13, 2013
Paper Number: SPE-165421-MS
... on a crusade seeking an alternative to a conventional rod driven PC Pump. This crusade has led to the development of a Rod-less PCP system, allowing the full benefit of the pumps ability to handle solids, while eliminating the primary cause of failure: the rod string. A major requirement to effectively...
Proceedings Papers

Paper presented at the SNAME Maritime Convention, October 30–November 1, 2019
Paper Number: SNAME-SMC-2019-057
... Tanks and critical spaces requiring a MIL-PRF-23236 Type VII Ultra High Solids (UHS) epoxy coating system have the option of retaining a Pre-Construction Primer (PCP) or the first coat of a multi coat Type VII UHS system throughout unit construction. PCP is not intended to last longer than 6...
Proceedings Papers

Paper presented at the SPE Progressing Cavity Pumps Conference, August 25–27, 2013
Paper Number: SPE-165654-MS
... Abstract Although conventional rod driven Progressing Cavity Pumps (PCPs) have been in use since the early 1980‘s, the industry has continued to seek alternative methods of powering the system. Initial attempts were made using conventional electric submersible induction motors however...
Proceedings Papers

Paper presented at the SPE/ICoTA Well Intervention Conference and Exhibition, March 26–27, 2019
Paper Number: SPE-194279-MS
... lift system downhole intervention Upstream Oil & Gas debris removal tool flow rate pressure loss bailer configuration turbine pump configuration valve coiled tubing slurry PCP debris type Introduction The problems caused by wellbore debris are well documented, and many...
Proceedings Papers

Paper presented at the SPE Artificial Lift Conference and Exhibition - Americas, November 10–12, 2020
Paper Number: SPE-201146-MS
... operational processes and design considerations. The following topics will be discussed: Design of wells with PCP as the artificial lift system Failure analysis Lifting Cost Challenge of artificial lifting Redesign of sucker rod string configuration This problem represents high lifting...
Proceedings Papers

Paper presented at the SPE Middle East Artificial Lift Conference and Exhibition, October 25–26, 2022
Paper Number: SPE-206961-MS
... neural network pmm sustainability sustainable development application upstream oil & gas artificial intelligence torque efficiency esp pmm finland dtc pcp application helsinki social responsibility artificial lift system submersible motor control accuracy rotation...
Proceedings Papers

Paper presented at the SPE Artificial Lift Conference and Exhibition - Americas, August 28–30, 2018
Paper Number: SPE-190964-MS
... stator society of petroleum engineers geometry PCP system Viability Acceptance Criteria installation control point application artificial lifting system configuration Introduction At present, the La Cira Infantas Field has 1125 active wells, of which 175 wells operate with artificial...
Proceedings Papers

Paper presented at the International Petroleum Technology Conference, December 7–9, 2009
Paper Number: IPTC-14076-MS
... found benefit in the efficiency of the flushby, then continued to spread into the rest of North America and, now, globally. Configuration Both at surface and downhole, the flushby can be stand-alone equipment on the job to service PCP systems and reciprocating-rod-pump (RRP) systems. In addition...
Proceedings Papers

Paper presented at the SPE Latin America and Caribbean Petroleum Engineering Conference, May 21–23, 2014
Paper Number: SPE-169336-MS
... monitoring artificial lift system Reservoir Surveillance gas separator Efficiency elastomer downhole gas separator gas production viscosity Petropiar production control Upstream Oil & Gas separator Huyapari field application gas Bubble PCP configuration separation crude oil horizontal...
Proceedings Papers

Paper presented at the SPE Oil and Gas India Conference and Exhibition, April 4–6, 2017
Paper Number: SPE-185431-MS
.... Installation of Insert PCP Installation of an I-PCP was a viable and economical option. Insert PCP systems currently available fall in two categories: Insert PCP with Anchor: The configuration comes with an anchor system which could be set/unset at any depth. However it was only available for 2-7/8" and 3...
Proceedings Papers

Paper presented at the SPE Artificial Lift Conference & Exhibition-North America, October 6–8, 2014
Paper Number: SPE-171344-MS
... required for running PCP system was commissioned prior to installation of the rods, which reduced the anticipated downtime for the wells. The commissioning of surface equipment included site acceptance testing of VFD, configuration of VFD, electrical cable identification and installation, digital signal...
Proceedings Papers

Paper presented at the SPE Progressing Cavity Pumps Conference, August 25–27, 2013
Paper Number: SPE-165648-MS
... footprint and environmental impact of the well. It also reduces deployment and workover requirements; resulting in fewer and safer operations. By combining unique technology and a novel configuration an ES-PCP system has been developed which reduces total cost of ownership. The system has entered field...
Proceedings Papers

Paper presented at the Canadian International Petroleum Conference, June 7–9, 2005
Paper Number: PETSOC-2005-096
... Abstract "Hollow Rod" technology was developed as a solution for the following applications: PCP Pumping Conventional sucker rods working under torsion loads arecommonly used to drive PCP pumping systems. Conventional rods have been developed to work under alternating tensile stress...
Proceedings Papers

Paper presented at the SPE International Heavy Oil Symposium, June 19–21, 1995
Paper Number: SPE-30275-MS
... Abstract It is common knowledge that some of the obstacles that must be overcome to successfully operate Progressing Cavity Pumping (PCP) Systems are attributed to conventional sucker rod couplings and the upset area around them. This paper addresses how the use of continuous sucker rod...
Proceedings Papers

Paper presented at the SPE Heavy Oil Conference-Canada, June 11–13, 2013
Paper Number: SPE-165469-MS
... losses due to seal friction, system inertia and casing to rod contact can result in additional intervention and OPEX. Electrical Submersible Pump applications for PCP system provides a viable alternative for many of these challenges by overcoming the limitations of conventional top drive systems...
Proceedings Papers

Paper presented at the SPE Mid-Continent Operations Symposium, March 28–31, 1999
Paper Number: SPE-52162-MS
... of the system and the dynamic fluid level of the well. The Field Hardware The field computer or RCU (Remote Control Unit) communicates with the VFD to control the speed of the drive motor and to monitor power usage by the system. The RCU is configured to store data and to operate the PCP system based...
Proceedings Papers

Paper presented at the SPE Artificial Lift Conference and Exhibition - Americas, November 10–12, 2020
Paper Number: SPE-201122-MS
.... The string used had a configuration similar to a typical Progressive Cavity Pump (PCP), with the pump being driven around 1,100 rpm by an electric motor located at the wellhead, through a sucker rod string. The paper will address all relevant information gathered during field operation. The procedure...
Proceedings Papers

Paper presented at the International Petroleum Technology Conference, March 23–April 1, 2021
Paper Number: IPTC-21827-MS
... o Pump 80K1800 (80 m 3 /100 RPM/day, and 1800m as max. lifting capacity) (See Fig. 3 , System Configuration) After artificial lift method changes to PCP on candidate well in August 2018, the operational parameters showing during system started up were; speed 120 RPM, torque 350 lb.ft...

Product(s) added to cart

Close Modal