Skip Nav Destination
Close Modal
Update search
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- EISBN
- ISSN
- EISSN
- Issue
- Volume
- References
- Paper Number
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- EISBN
- ISSN
- EISSN
- Issue
- Volume
- References
- Paper Number
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- EISBN
- ISSN
- EISSN
- Issue
- Volume
- References
- Paper Number
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- EISBN
- ISSN
- EISSN
- Issue
- Volume
- References
- Paper Number
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- EISBN
- ISSN
- EISSN
- Issue
- Volume
- References
- Paper Number
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- EISBN
- ISSN
- EISSN
- Issue
- Volume
- References
- Paper Number
NARROW
Format
Subjects
Article Type
Date
Availability
1-5 of 5
Keywords: fatigue test
Close
Follow your search
Access your saved searches in your account
Would you like to receive an alert when new items match your search?
Sort by
Proceedings Papers
Coiled Tubing Premature Failure – The Effects of Pressure and Strain
Available to PurchaseJorge Martin Bunge, Mariano Coloschi, Sebastian Cravero, Martin Valdez, Bruce Reichert, Carmen Grimaldo
Publisher: Society of Petroleum Engineers (SPE)
Paper presented at the SPE/ICoTA Well Intervention Conference and Exhibition, March 22–23, 2022
Paper Number: SPE-208996-MS
... parted became very common. Figure 1 shows the crack length vs the normalized hoop stress for the fatigue tests performed for this analysis. It is important to note that as the samples were obtained after the CT had been placed on a reel, it was not always possible to position the ERW weld...
Proceedings Papers
Modern Wireline Cables and Their Qualification Processes
Available to PurchasePublisher: Society of Petroleum Engineers (SPE)
Paper presented at the SPE/ICoTA Well Intervention Conference and Exhibition, March 24–25, 2020
Paper Number: SPE-199801-MS
... be grouped in the following categories: Cable strength and comprehensive fatigue tests Cable constructional stretch removal process Live well-control running qualification process In this paper, we will elaborate on the design of the specific cable design changes, qualification tests, post...
Proceedings Papers
Rotation and Diameter Growth of Coiled Tubing
Available to PurchasePublisher: Society of Petroleum Engineers (SPE)
Paper presented at the SPE/ICoTA Coiled Tubing and Well Intervention Conference and Exhibition, March 27–28, 2018
Paper Number: SPE-189948-MS
... included in CT fatigue models. The CT also experiences diametrical growth and elongation. Almost all fatigue testing is done without rotating the CT sample. Diameter growth models based on these fatigue tests have over predicted the amount of diametrical growth. This ongoing work has already shown...
Proceedings Papers
CT Fatigue Modeling Update
Available to PurchasePublisher: Society of Petroleum Engineers (SPE)
Paper presented at the SPE/ICoTA Coiled Tubing and Well Intervention Conference and Exhibition, March 22–23, 2016
Paper Number: SPE-179049-MS
... that has been implemented and is now being used by a significant portion of the CT industry. material model Upstream Oil & Gas fatigue model strain range bias weld model diametrical growth fatigue life stress strain range base material model fatigue test point manufacturer life...
Proceedings Papers
Full-Scale Coiled Tubing Fatigue Tests With Tubing Pressures to 15,000 Psi
Available to PurchasePublisher: Society of Petroleum Engineers (SPE)
Paper presented at the SPE/ICoTA Coiled Tubing Roundtable, May 25–26, 1999
Paper Number: SPE-54482-MS
... Abstract In recent years, the performance envelope of coiled tubing (CT) has expanded because of improvements in tubing manufacture and the prediction of low-cycle fatigue life. More accurate life predictions have been achieved with data from laboratory-scale and full-scale CT fatigue tests...