1-20 of 32
Keywords: flow loop
Close
Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 21–23, 2021
Paper Number: SPE-205914-MS
... are created in response to a larger drawdown. The result is a density-AICD that will operate in real-world conditions, especially in the light oil formations of the Middle East. The performance of this novel density-AICD has been measured in flow loop testing and demonstrated in computer modeling. The flow...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, October 26–29, 2020
Paper Number: SPE-201534-MS
... to track the thermal slugging in single-phase (liquid) and two-phase (gas and liquid) flow within a vertical wellbore to estimate flow velocity and characterize multiphase flow behavior. A vertical flow loop is constructed for this research, which consists of a 7-m long transparent polyvinyl chloride (PVC...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 30–October 2, 2019
Paper Number: SPE-196216-MS
... of FCDs is a truly Autonomous Inflow Control Valve (AICV) which can optimize oil production, reduce SOR and significantly restrict the inflow of unwanted fluids such as water, steam and Non-condensable Gases (NCGs). This novel AICV design was tested in a full-scale high temperature laboratory flow loop...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 30–October 2, 2019
Paper Number: SPE-196224-MS
... co2-ng pilot facility bara operation Blockage society of petroleum engineers Reservoir Surveillance blowdown carbon dioxide Simulation buffer vessel flow loop warm section cold section Scenario Introduction As conventional gas resources around the world are depleting...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 30–October 2, 2019
Paper Number: SPE-196072-MS
... flow loop thermal method Reservoir Surveillance Upstream Oil & Gas steam-limiting flow control device phase change application conformance restriction steam quality C-FER FCD SAGD Performance Characterization FCD characterization testing at C-FER originally began with a focus...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, October 9–11, 2017
Paper Number: SPE-187252-MS
... Physical Properties Values API Gravity (°) 43 WAT or Cloud Point 38 Wax Content (Wt. %) 9 Flash Point (°C) 10 Mass flux behavior and the performance of paraffin inhibitors are investigated using cold finger apparatus and laboratory scale flow loop. The detailed description...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 26–28, 2016
Paper Number: SPE-181581-MS
... technology at ‘real’ conditions and scale. And third party Flow-loop testing has been decided since it is already considered by the industry as the "proper" way of performing such technology assessment and benchmarking since the accuracy of the reference measurement system is guaranteed with the required...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 26–28, 2016
Paper Number: SPE-181553-MS
... different leak size leak size pressure level air emission mathematical model acoustic processing twin ball technology sensor acoustic level smart ball experiment assembly flow loop propagation Abstract Healing leaks is always a priority in the oil and gas industry and plays a major...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, October 8–10, 2012
Paper Number: SPE-160317-MS
..., which was completed in the high-temperature flow loop at C-FER Technologies. Accurately monitoring the internal temperature of the ESP motor is a key consideration when trying to increase the operational longevity of an ESP system for any application; however, as the SAGD process develops...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, October 8–10, 2012
Paper Number: SPE-159583-MS
... downhole condition data collector tracer injection system initiator surface device spe 159583 drilling fluid shale shaker flow loop battery drill bit nozzle microchip system Introduction Modern exploration and production of oil/gas reserves require well-managed drilling operations...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 19–22, 2010
Paper Number: SPE-134528-MS
... Both the 2008 and 2009 test programs were completed in the high-temperature flow loop at C-FER Technologies in Edmonton, Alberta. Since this high-temperature flow loop was built in 2004, it has been upgraded for higher temperature testing in 2007 and in 2009 through funding provided...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, October 4–7, 2009
Paper Number: SPE-123735-MS
... ESP motor ConocoPhillips performance curve artificial lift system resistance system shutdown real time system fluid temperature pump speed operation reliability test test program flow loop ESP system society of petroleum engineers Upstream Oil & Gas flow rate control system...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, November 11–14, 2007
Paper Number: SPE-110116-MS
... this theoretical effort, experimental measurements are required to verify multiphase flow models under controlled conditions and assess their range of applicability. This is why there exists a large number of multiphase flow loops around the world. However, there are numerous varieties of multiphase flow...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, November 11–14, 2007
Paper Number: SPE-109840-MS
.... Volumetric cuttings concentration in the test section and frictional pressure losses were measured during the tests using two nuclear densitometers and a differential pressure transducer. A total of 116 experiments were conducted on a full-scale, High-Pressure High-Temperature Flow Loop (57.4-feet long...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 24–27, 2006
Paper Number: SPE-103037-MS
... . Evaluating friction reducers in coiled tubing normally requires full-scale flow loop testing. A friction reducer can significantly reduce the friction pressure loss of a fluid across the tubing. The full-scale loop can produce representative data on straight or coiled tubing under various injection rates...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 24–27, 2006
Paper Number: SPE-103151-MS
... As a compliment to the CSM flow loop, a Centrilift ESP test well ( Fig. 5 ) was adapted to confirm the CSM tests. The test well was equipped to simulate gas and liquid entry in the annulus above the pump as shown in Fig. 6 . The liquid and gas are injected into the system after being measured...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 24–27, 2006
Paper Number: SPE-101220-MS
... experiments were conducted under simulated downhole conditions. The University of Tulsa Advanced Cutting Transport Facility (ACTF) flow loop (73-ft-long test section with annular geometry of 5.76″ × 3.5″) was used to simulate downhole conditions. Three types of sweep tests were conducted with six drilling...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, October 9–12, 2005
Paper Number: SPE-96938-MS
... Abstract Effective removal of water and hydrocarbon liquids from gas wells can maintain and increase gas production. In this paper, results of flow loop tests on transport of liquid from casing to tubing is reported for flow rates ranging from 50% below to 50% above the critical gas flow rate...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 26–29, 2004
Paper Number: SPE-90992-MS
... rate and water-cut predictions are made with an acceptable accuracy with no additional measurements. The wet-gas and low-liquid-volume-fraction interpretation model is described together with the multiphase flow meter. Examples are presented of applying this model to data collected on flow loops...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 29–October 2, 2002
Paper Number: SPE-77655-MS
... reliable continuous measurements of downhole flow rates in producing wells have not generally been available because of difficulties in designing and deploying measurement devices for hostile in-well environments. This paper discusses the design, operating principles, and flow loop testing of the world's...

Product(s) added to cart

Close Modal