1-20 of 114
Keywords: detector
Close
Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 23–25, 2024
Paper Number: SPE-220727-MS
... Abstract Sand production in oil and gas wells and erosion of pipelines and fittings caused by sand impact is one of the most common and expensive problems for the oil and gas industry. Acoustic sand detectors (ASD) are commonly used to provide a warning/alarm when sand is being produced...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 23–25, 2024
Paper Number: SPE-220699-MS
... and shows the impact on the phase behavior calculations. Based on this analysis, qualitative guidelines can be made on what compositional uncertainties have the biggest impact on the different fluid types and phase behavior properties. geology detector gravity geologist geological subdiscipline...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, October 16–18, 2023
Paper Number: SPE-214893-MS
... algorithms utilizing model-based design. While neutron-porosity tools are characterized by nuclear simulation techniques since several decades, gamma-gamma density logging-while drilling tools, typically employing a 137 Cs logging source and two scintillation gamma-ray detectors, are often characterized...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 21–23, 2021
Paper Number: SPE-206383-MS
... tool for pipes and multiples casing for metal loss detection. This state-of-the-art technology is a noticeable improvement over existing tools, due to an important increase in the number of sources, number of detectors and wide range of working frequencies. The combination of these changes allows...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 30–October 2, 2019
Paper Number: SPE-196047-MS
... sensitivity vertical resolution SMP fixture detector neutron attenuation response base pipe well logging hydrogen concentration shape memory polymer expansion limestone block Introduction The new shape memory polymer (SMP) sandface completion is now a field proven alternative...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 30–October 2, 2019
Paper Number: SPE-196090-MS
... gas condensate reservoir depletion. Conventional thermal neutron capture cross section (Sigma) has low sensitivity to gas density variations, making it unable to detect reservoir pressure changes. Upstream Oil & Gas log analysis depletion water saturation detector reservoir pressure cc...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 30–October 2, 2019
Paper Number: SPE-195806-MS
... analysis or a flame ionization detector for a complete assay. Isotope analysis is also possible. Recovery to surface of fluid samples collected at reservoir temperature and pressure allows for analysis with an automated gas chromatograph (GC) deployed in the field, providing reduced labor and rapid...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 30–October 2, 2019
Paper Number: SPE-196007-MS
... to 25,000 psi while minimizing the attenuation of formation gamma rays entering the detector and maintaining good azimuthal sensitivity. The tool uses a robust, constrained, weighted least-squares (WLS) analysis to derive elemental concentrations from measured pulse-height gamma ray spectra. Proprietary...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 30–October 2, 2019
Paper Number: SPE-195950-MS
... Abstract A new cased-hole porosity measurement has been developed for a four-detector pulsed-neutron logging tool. The measurement is based on a capture count rate ratio from two different detectors. To determine an accurate porosity, the ratio is characterized in the laboratory in order...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 24–26, 2018
Paper Number: SPE-191595-MS
... measurement. Based on these experiments, an X-ray source and detector were identified and a sensor was designed for inline use on 4 inch pipes. Two approaches were developed to estimate density using the sensor. The first was an empirical approach where sensor gray level values were directly mapped onto mud...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 24–26, 2018
Paper Number: SPE-191438-MS
... Abstract The determination of elemental concentrations, mineralogy and lithology is essential for the evaluation of unconventional plays. Several instruments utilizing D-T generator and gamma ray detectors have been developed to determine elemental weight fractions. The measured gamma ray...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 24–26, 2018
Paper Number: SPE-191738-MS
... Abstract Sigma logging is a proven method for determining oil/water saturation behind casing. In this paper, we present a new, diffusion-corrected, sigma algorithm for a four-detector pulsed-neutron logging tool. Since the diffusion effect is inversely related to the distance between source...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 24–26, 2018
Paper Number: SPE-191707-MS
... hydraulic fracturing axial extent well logging Completion Installation and Operations Upstream Oil & Gas count rate signal fracture height log analysis proppant detector fracturing fluid modeling nrt signal proppant placement borehole axis fracture plane horizontal well wellbore depth...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, October 9–11, 2017
Paper Number: SPE-187114-MS
...-detector spacing for maximum accuracy. The tool design comprises a 14 MeV neutron source, two gamma ray detectors and two fast neutron detectors. Counts ratios are used to establish a linear relationship with formation bulk density. This design yields an accuracy of 0.0147 g/cm 3 in shale-free formations...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 26–28, 2016
Paper Number: SPE-181409-MS
.... The Mark 1 Sensabot was delivered in 2011 and contained an array of cameras, gas detectors, a vibration detector and a microphone. Trials of this robot were very successful so the development project was continued resulting in a manipulation arm and Sensabot Mark 2. The latter is now proceeding through...
Proceedings Papers

Paper presented at the SPE Annual Technical Conference and Exhibition, September 26–28, 2016
Paper Number: SPE-181279-MS
... detector neutron-gamma density measurement formation evaluation Drilling log analysis specification GGD measurement density measurement Reichel limitation NGD society of petroleum engineers Introduction The LWD engineering effort started in the late 1970s, and was initially staffed...

Product(s) added to cart

Close Modal