1-20 of 53
Keywords: magnetometer
Close
Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Proceedings Papers

Paper presented at the SEG/AAPG/SEPM First International Meeting for Applied Geoscience & Energy, September 26–October 1, 2021
Paper Number: SEG-2021-3594946
... and are not sensitive to the transient electromagnetic system to detect an underground rotation of airborne magnetometers. In order to study the cavity (mining tunnel) in a mining area. feasibility of SA-MMR, we design a mountain model containing a low-resistivity fracture zone. The positive and So far, most semi...
Proceedings Papers

Paper presented at the SEG/AAPG/SEPM First International Meeting for Applied Geoscience & Energy, September 26–October 1, 2021
Paper Number: SEG-2021-3594781
... characterization applied geoscience component squid sensor thomson instrument exploration geophysicist 10 field component seg technical program expanded abstract airborne natural field electromagnetic geophysics magnetometer bandwidth Three component SQUID based system for Airborne Natural Field...
Proceedings Papers

Paper presented at the SEG/AAPG/SEPM First International Meeting for Applied Geoscience & Energy, September 26–October 1, 2021
Paper Number: SEG-2021-W6-05
... magnetometry upstream oil & gas magnetic field application sensor resolution operation stolz magnetometer noise gradiometer magnetic gradiometry ftmg instrument metals & mining instrument exploration geophysicist 10 gradiometry schultze gradient Status and future perspectives...
Proceedings Papers

Paper presented at the SEG International Exposition and Annual Meeting, October 11–16, 2020
Paper Number: SEG-2020-3427148
... Cesium optically pumped magnetometers are widely used in the field of geophysical exploration. However, the accuracy and sampling rate of optical magnetic resonance lamor signal limit the improvement of magnetometers. In order to solve this problem, this paper analyzes the formation mechanism...
Proceedings Papers

Paper presented at the 2018 SEG International Exposition and Annual Meeting, October 14–19, 2018
Paper Number: SEG-2018-2998607
... vehicle (UAV). Aeromagnetic data of the Stillwater landfill was collected and a grid map was created to delineate its boundaries. A walking survey was also conducted to compare the smartphone with a G858 Cesium vapor magnetometer. Results showed little variation between the two sensors when within...
Proceedings Papers

Paper presented at the 2017 SEG International Exposition and Annual Meeting, September 24–29, 2017
Paper Number: SEG-2017-17789107
... smartphone sensors with the potential for geophysical applications include the accelerometer, magnetometer, red-green-blue (RGB) sensor, and barometer. Although many free applications (apps) like AndroSensor can be downloaded to view and record the information from these sensors, only one published article...
Proceedings Papers

Paper presented at the 2016 SEG International Exposition and Annual Meeting, October 16–21, 2016
Paper Number: SEG-2016-13850871
... performance and the minimum index requirements of these parameters. Presentation Date: Tuesday, October 18, 2016 Start Time: 11:35:00 AM Location: 161 Presentation Type: ORAL technical specification gradiometer magnetic field magnetometer low system noise specification attitude measurement...
Proceedings Papers

Paper presented at the 2016 SEG International Exposition and Annual Meeting, October 16–21, 2016
Paper Number: SEG-2016-13947186
... Academy of Sciences (CAS), CHINA Summary Here we report a low-temperature-superconducting (LTS) SQUID based full tensor gradient system. A symmetrical configuration is used with six planar-type gradiometers mounted on the different faces of a hexagonal-pyramid. A tri-axial SQUID magnetometer was used...
Proceedings Papers

Paper presented at the 2016 SEG International Exposition and Annual Meeting, October 16–21, 2016
Paper Number: SEG-2016-13607329
... altitude carleton university aeromagnetic survey flight aerospace & defense stratus aeronautics unmanned aircraft system michael cunningham upstream oil & gas unmanned aircraft system magnetometer aeromagnetic data experimental aeromagnetic survey flight line skylance ua...
Proceedings Papers

Paper presented at the 2016 SEG International Exposition and Annual Meeting, October 16–21, 2016
Paper Number: SEG-2016-13778841
... movement metals & mining transverse gradient seg seg international exposition rotational movement gradient frequency notch filter air transportation translational movement magnetometer Hardwick , C. D. , 1984 , Important design considerations for inboard airborne magnetic...
Proceedings Papers

Paper presented at the 2011 SEG Annual Meeting, September 18–23, 2011
Paper Number: SEG-2011-0806
... oldenburg magnetization constraint imaging cross section velocity michele sji application magnetometer reservoir characterization magnetic inversion gravity inversion Simultaneous joint inversion for susceptibility and velocity Michele De Stefano , WesternGeco Summary I describe...
Proceedings Papers

Paper presented at the 2011 SEG Annual Meeting, September 18–23, 2011
Paper Number: SEG-2011-0861
... which has the same magnetometers and sensor geometry as planned for the UAS. A test survey was conducted using the simulated UAS and the total magnetic intensity (TMI) data recorded were compared to that obtained during a conventional regional fixed-wing survey and a ground survey. Transverse magneto...
Proceedings Papers

Paper presented at the 2011 SEG Annual Meeting, September 18–23, 2011
Paper Number: SEG-2011-0791
... distribution schmidt magnetite skarn magnetometer reservoir characterization 3D inversion of full tensor magnetic gradiometry (FTMG) data Michael S. Zhdanov, University of Utah and TechnoImaging, Hongzhu Cai*, University of Utah, and Glenn A. Wilson, TechnoImaging Summary Following recent advances...
Proceedings Papers

Paper presented at the 2010 SEG Annual Meeting, October 17–22, 2010
Paper Number: SEG-2010-0800
... bit converter. Flux- gate magnetometers provide a high precision stable simulta- neous measure of the 3 components of the magnetic field at 50 Hz. The receiver was tested for both marine magnetotel- luric (MT) and Controlled Source ElectroMagnetic (CSEM). We report on results obtained in sub-basalt...
Proceedings Papers

Paper presented at the 2010 SEG Annual Meeting, October 17–22, 2010
Paper Number: SEG-2010-1167
... flight testing altitude geosurv ii prototype air transportation reservoir characterization aerospace & defense magnetometer artificial intelligence carleton university simulated ua upstream oil & gas fuselage seg seg denver 2010 configuration simulated ua data canada...
Proceedings Papers

Paper presented at the 2010 SEG Annual Meeting, October 17–22, 2010
Paper Number: SEG-2010-3848
... northern thailand geophysics archaeological geophysics workshop data collection participant interpretation reservoir characterization chiang mai wiang kum kam seg seg denver 2010 wat pan sao university thailand magnetometer Student-based archaeological geophysics in northern...
Proceedings Papers

Paper presented at the 2009 SEG Annual Meeting, October 25–30, 2009
Paper Number: SEG-2009-0790
... laboratory upstream oil & gas sensor reservoir characterization electromagnetic innovation strack information kms technology international exposition confidence interval fluxgate magnetometer search coil magnetometer miniaturization seg houston 2009 magnetometer fluxgate...
Proceedings Papers

Paper presented at the 2008 SEG Annual Meeting, November 9–14, 2008
Paper Number: SEG-2008-2889
... restriction. The Military Munitions Response Program is charged with characterizing and, where necessary, remediating munitions-contaminated sties. When a site is cleaned up, it is typically mapped with a geophysical system, based on either a magnetometer or electromagnetic induction sensor, for the purposes...
Proceedings Papers

Paper presented at the 2008 SEG Annual Meeting, November 9–14, 2008
Paper Number: SEG-2008-1132
..., 2.5 nm) optically filtered images in a wavelength region, typically from 100 nm to 2.3 um. The weight of such a system is typically 6.3 kg, to which one adds around 2.7 kg for additional optics and electronics, to get an estimated total weight of 9 kg. The Cesium magnetometer provides a very precise...

Product(s) added to cart

Close Modal