1-5 of 5
Keywords: arrangement
Close
Sort by
Proceedings Papers

Paper presented at the PSIG Annual Meeting, November 7–9, 2005
Paper Number: PSIG-0504
... the accommodation of the request for extra capacity. In light of this, a transient model was developed which facilitated determination of a suitable network arrangement. In summary, the paper is an example of how using transient analysis facilitates asset optimization in a gas transmission network. INTRODUCTION...
Proceedings Papers

Paper presented at the PSIG Annual Meeting, October 20–22, 2004
Paper Number: PSIG-0405
... Arrangemente on Station #6 Capacity PSIG 0405 Series or Parallel Arrangement for a Compressor Station? A Recurring Question that needs a Convincing Answer 9 950 1000 1050 1100 1150 1200 1250 1300 1350 1400 1030 1040 1050 1060 1070 1080 1090 1100 1110 1120 7450 7500 7550 7600 7650 7700 7750 7800 7850 7900...
Proceedings Papers

Paper presented at the PSIG Annual Meeting, October 15–17, 2003
Paper Number: PSIG-03A2
... turbines or variable fre- quency electric motors. Both series and parallel arrangements are analyzed in a tran- sient simulation mode to determine which operation mode is more advantageous. The simulation involves the modeling of the station and compressors, as well as the pipeline segments upstream...
Proceedings Papers

Paper presented at the PSIG Annual Meeting, October 28–30, 2000
Paper Number: PSIG-0001
... and failure analysis determined a selection of a parallel arrangement for the fourteen (14) compressor stations with four (4) 7000 hp ISO gas turbines per station. The project schedule considered the installation of three (3) initial compressor stations that were necessary for three (3) years of operation...
Proceedings Papers

Paper presented at the PSIG Annual Meeting, October 15–17, 1997
Paper Number: PSIG-9703
... the schedule of placing compression stations and units into operation depending on the gas build up delivery. Additionally we may use the transient analysis to make a pre-definition of the turbo compres- sors that best fit our system and also define the best arrangement for the units in the station, whether...