1-20 of 328
Keywords: installation
Close
Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Proceedings Papers

Paper presented at the CORROSION 2019, March 24–28, 2019
Paper Number: NACE-2019-12820
... Subsurface Corrosion materials and corrosion multi-array sensor probe corrosion rate permission flowline corrosion riser corrosion Publication Division texas 77084 Anchor maximum corrosion rate Houston Pipeline Corrosion well integrity probe installation Probe Bridge manuscript...
Proceedings Papers

Paper presented at the CORROSION 2019, March 24–28, 2019
Paper Number: NACE-2019-12822
... & Gas texas 77084 Probe Houston installation oil storage tank multi array sensor coupon manuscript storage tank average corrosion rate tank Corrosion Monitoring of Oil Storage Tanks C. Sean Brossia INVISTA, Sarl 15710 John F Kennedy Blvd Houston, TX, 77032 United States Dingrong Qu...
Proceedings Papers

Paper presented at the CORROSION 2019, March 24–28, 2019
Paper Number: NACE-2019-12827
... cathodic protection configurations are used worldwide in tanks. The field-erected mixed metal oxide (MMO) anode welded grid configuration was an early application of MMO anodes for tank bottoms and has a large global installed base. A newer design to protect tank bottoms is a system of parallel...
Proceedings Papers

Paper presented at the CORROSION 2019, March 24–28, 2019
Paper Number: NACE-2019-12904
... ABSTRACT Pipeline owners use the HDD (Horizontal Directional Drilling) installation method at locations where surface obstructions or access limitations preclude conventional trenched-in construction. Linear water crossings, such as creeks, rivers, and streams, are most commonly crossed using...
Proceedings Papers

Paper presented at the CORROSION 2019, March 24–28, 2019
Paper Number: NACE-2019-12934
... for permanent subsea installation on an 8-inch elbow to monitor the pipe integrity and detect erosion by measuring the critical elbow wall loss. Monitoring tool consists of multiple (seven) ultrasound sensor segments spread around the outside circumference of the elbow, and each contain 34 ultrasound...
Proceedings Papers

Paper presented at the CORROSION 2019, March 24–28, 2019
Paper Number: NACE-2019-12986
... Internal Installation Pressure Effects on Composite Repairs Bradley Whelan Neptune Research Inc. 3875 Fiscal Court, Suite 100 Riviera Beach, FL 33404 USA ABSTRACT Most composite repair installations take place with some amount of pressure in the pipe. The traditional design standards, ASME PCC-2...
Proceedings Papers

Paper presented at the CORROSION 2019, March 24–28, 2019
Paper Number: NACE-2019-13002
... mesh anode H2S management reinforcement steel anode Pipeline Corrosion Production Chemistry current distributor bar installation manuscript Upstream Oil & Gas rebar rehabilitation permission Houston 1 Cathodic Protection Retrofit for Rehabilitation of Aging Reinforced Concrete...
Proceedings Papers

Paper presented at the CORROSION 2019, March 24–28, 2019
Paper Number: NACE-2019-13085
... they are properly installed and maintained. Galvanic cathodic protection systems are sometimes portrayed to provide only limited protection for a short period of time, but properly designed and installed galvanic systems can provide cathodic protection performance benefits with minimal annual maintenance and anode...
Proceedings Papers

Paper presented at the CORROSION 2019, March 24–28, 2019
Paper Number: NACE-2019-13136
..., installers and the end users has continued to increase as well. The information to be discussed looks to address the best practices of the industry by briefly examining each major step within the repair process and highlighting key aspects that are often overlooked or not considered important. Intended...
Proceedings Papers

Paper presented at the CORROSION 2019, March 24–28, 2019
Paper Number: NACE-2019-13137
... present during the installation phase and some of the more significant issues will be discussed in further detail. Once the composite repair was applied and inspected, a top-coat was applied. After approximately one year, the entire repair was repeated on top of the existing repair to provide further...
Proceedings Papers

Paper presented at the CORROSION 2019, March 24–28, 2019
Paper Number: NACE-2019-13187
... Interpretation of Electrical Codes for Cathodic Protection Installations Matthew Viveiros Corrpro Canada, Inc. 11405 163 ST NW Edmonton, AB, T5M 3Y3 Canada Stephen B. Gibson Corrpro Canada, Inc. 11405 163 ST NW Edmonton, AB, T5M 3Y3 Canada Natanael Melendez Corrpro Canada, Inc. 310 Wall Street...
Proceedings Papers

Paper presented at the CORROSION 2019, March 24–28, 2019
Paper Number: NACE-2019-13244
... permission materials and corrosion ground transportation abrasion field joint coating HDD installation Houston gouge Upstream Oil & Gas composite coating Publication Division coating damage manuscript Advances in Field Joint Coatings for HDD with Composite Coatings Davie Peguero NRI 3875...
Proceedings Papers

Paper presented at the CORROSION 2019, March 24–28, 2019
Paper Number: NACE-2019-13406
... and industries. It discusses the different philosophies between the energy and water industries associated with the installations and subsequent monitoring of casings. Assumptions made during design phases are compared. Case studies on the evaluation of the effectiveness of different installation and operations...
Proceedings Papers

Paper presented at the CORROSION 2019, March 24–28, 2019
Paper Number: NACE-2019-13391
... Abstract Pipeline installation by Horizontal Directional Drilling (HDD), has progressively gained a lot of popularity over the last three decades. Sound engineering practices, site condition, client preference and safety considerations can dictate the use of HDD methodology for installing...
Proceedings Papers

Paper presented at the CORROSION 2019, March 24–28, 2019
Paper Number: NACE-2019-13554
... ABSTRACT Trenchless technologies are increasingly used to install pipelines at crossings with environmentally sensitive features, highways, etc. For deep crossings installed in rock via horizontal directional drilling (HDD), there has been concern within the pipeline industry about...
Proceedings Papers

Paper presented at the CORROSION 2018, April 15–19, 2018
Paper Number: NACE-2018-11057
... facilities in soils is provided by protective coatings and cathodic protection. Also, the 4 sea ports with harbour and jetty installations are being operated. More than 7000 cathodic protection rectifiers with impressed current anodic groundings provide necessary protective current, and more than 60000...
Proceedings Papers

Paper presented at the CORROSION 2018, April 15–19, 2018
Paper Number: NACE-2018-11120
... a solution to significantly reduce the internal corrosion of such areas using a highly sophisticated ICCP system. This paper also covers various other technical, electrochemical and installation challenges in the implementation of such an ICCP system within confined spaces. This solution was developed...
Proceedings Papers

Paper presented at the CORROSION 2018, April 15–19, 2018
Paper Number: NACE-2018-11271
... the impact on the AC effects. However, instead, it was decided to proceed with the design and installation of a large-scale AC mitigation system. The analysis/design lasting several months was based on extensive field studies to evaluate pipe and soil characteristics, AC and DC influences, and power line...
Proceedings Papers

Paper presented at the CORROSION 2018, April 15–19, 2018
Paper Number: NACE-2018-10818
... of requirements set forth in the ASME Post Construction Code 2 (PCC-2) 1 , Article 4.1 Nonmetallic Composite Repair Systems: High Risk Applications, is crucial for successful design, installation, and long-term service. Understanding the full range of requirements found within this document can provide a high...
Proceedings Papers

Paper presented at the CORROSION 2018, April 15–19, 2018
Paper Number: NACE-2018-11321
... should act as one integrated CP system unless isolation joints are installed, which is not common due to high cost and long fabrication lead time. Therefore, a systematic CP management program is often desired, to be studied and defined during design and implemented and managed during operation...

Product(s) added to cart

Close Modal