Skip Nav Destination
Close Modal
Update search
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- EISBN
- ISSN
- EISSN
- Issue
- Volume
- References
- Paper Number
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- EISBN
- ISSN
- EISSN
- Issue
- Volume
- References
- Paper Number
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- EISBN
- ISSN
- EISSN
- Issue
- Volume
- References
- Paper Number
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- EISBN
- ISSN
- EISSN
- Issue
- Volume
- References
- Paper Number
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- EISBN
- ISSN
- EISSN
- Issue
- Volume
- References
- Paper Number
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- EISBN
- ISSN
- EISSN
- Issue
- Volume
- References
- Paper Number
NARROW
Format
Subjects
Date
Availability
1-10 of 10
Keywords: high purity water
Close
Follow your search
Access your saved searches in your account
Would you like to receive an alert when new items match your search?
Sort by
Proceedings Papers
Publisher: NACE International
Paper presented at the CORROSION 2013, March 17–21, 2013
Paper Number: NACE-2013-2155
... ABSTRACT Hydrogen peroxide (H 2 O 2 ) is the most important oxidant to determine the corrosive environment of boiling water reactors (BWRs). Since H 2 O 2 is unstable at high temperature and electrochemical measurement in high purity water is difficult, H 2 O 2 polarization characteristics...
Proceedings Papers
Publisher: NACE International
Paper presented at the CORROSION 2009, March 22–26, 2009
Paper Number: NACE-09411
... and exposed to high temperature, high purity water at 360°C under constant load conditions. Specimens were also ring loaded to a K level of approximately 35 MPaÖm and exposed to high temperature high purity water at 338°C. SCC was observed in every specimen test with the exception of the 304L specimen cold...
Proceedings Papers
Publisher: NACE International
Paper presented at the CORROSION 2008, March 16–20, 2008
Paper Number: NACE-08600
... observed after several tens of thousands of hours at 300°C. The effect of thermal aging on mechanical properties, including tensile, toughness, fatigue and static crack growth has been investigated at room temperature and in 288°C high purity water simulating BWR operating conditions. The measurement...
Proceedings Papers
Publisher: NACE International
Paper presented at the CORROSION 2004, March 28–April 1, 2004
Paper Number: NACE-04565
... purity solution compared to the sulfate solutions. On these alloys, M3O4 formed in low dissolved oxygen solutions while a M2O3 film formed in high dissolved oxygen, similar to what has been observed in high purity water. Alloy 600 in the PWR experiments was polarized below an electrochemical potential...
Proceedings Papers
Publisher: NACE International
Paper presented at the CORROSION 2003, March 16–20, 2003
Paper Number: NACE-03667
... oxidation Corrosion Management specimen mass transport electrode current density high purity water hydrogen oxide layer noble metal reduction concentration coating nuclear power system-water reactor Intergranular stress Corrosion INTRODUCTION ABSTRACT The effect of surface property...
Proceedings Papers
Publisher: NACE International
Paper presented at the CORROSION 2001, March 11–16, 2001
Paper Number: NACE-01228
... ABSTRACT Stress corrosion crack growth studies have been performed in high temperature, ultra high purity water on unsensitized stainless steels and alloy 600 as a function of martensite, yield strength, corrosion potential, temperature, and hydrogen fugacity. Parallel experiments were...
Proceedings Papers
Publisher: NACE International
Paper presented at the CORROSION 2000, March 26–31, 2000
Paper Number: NACE-00665
... Corrosion Management calibration instrument Upstream Oil & Gas high purity sample temperature compensation pH Measurement leakage conductivity buffer solution electrode high purity water solution temperature compensation ON-LINE pH MEASUREMENT FOR STEAM GENERATING SYSTEMS David M. Gray...
Proceedings Papers
Publisher: NACE International
Paper presented at the CORROSION 99, April 25–30, 1999
Paper Number: NACE-99437
... concentration ppm NaNO oilfield chemistry Corrosion Management reactor high purity water oxide film impedance measurement Production Chemistry high temperature water polarization resistance Houston in-situ electrochemical impedance measurement Upstream Oil & Gas electrode ECP autoclave...
Proceedings Papers
Publisher: NACE International
Paper presented at the Corrosion97, March 9–14, 1997
Paper Number: NACE-97113
... ABSTRACT The polarization behavior of the redox reactions of hydrogen (H 2 ), oxygen (O 2 ), and hydrogen peroxide (H 2 O 2 ) on 304 stainless steel (SS) in high temperature, high purity water was studied in order to determine the electrochemical kinetic constants, such as Tafel slopes...
Proceedings Papers
Publisher: NACE International
Paper presented at the CORROSION 96, March 24–29, 1996
Paper Number: NACE-96265
... fracture mechanic specimens which were tested in high purity water in the temperature range of -1O°C to 320°C, depending on the alloy. Attention was directed towards region II behavior, where the crack propagation rate is independent of stress intensity but sensitive to test temperature. The experimental...