1-20 of 33
Keywords: glycol
Close
Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Proceedings Papers

Paper presented at the CORROSION 2019, March 24–28, 2019
Paper Number: NACE-2019-13289
... ABSTRACT Glycol systems are widely used in gas processing plants for the removal of contaminants such as moisture from the gas. Since the majority of the piping and vessels in these plants are fabricated from carbon steel, there is a high potential for corrosion. This paper provides a brief...
Proceedings Papers

Paper presented at the CORROSION 2018, April 15–19, 2018
Paper Number: NACE-2018-11223
... chemistry texas 77084 Publication Division consideration permission prediction Houston manuscript evaluation glycol Modeling & Simulation Upstream Oil & Gas corrosion rate condensation rate tlc corrosion rate flow model 1 Evaluation of Top-of-Line Corrosion Model for Multiphase Oil...
Proceedings Papers

Paper presented at the CORROSION 2017, March 26–30, 2017
Paper Number: NACE-2017-9419
... 2 S corrosion prediction model developed by the authors' organization. The TLC model determines the top of the line corrosion rate of carbon steel based on water chemistry and film-wise condensation rate. The effect of various glycols, such as Monoethylene Glycol (MEG), Diethylene glycol (DEG...
Proceedings Papers

Paper presented at the CORROSION 2016, March 6–10, 2016
Paper Number: NACE-2016-7891
... Abstract In wet gas pipelines, Monoethylene glycol (MEG) is a widely used hydrate inhibitor which has been shown to decrease the corrosion rate of carbon steel in CO2 environments. In a top of the line corrosion (TLC) situation, MEG is also known to affect both water condensation and TLC...
Proceedings Papers

Paper presented at the CORROSION 2015, March 15–19, 2015
Paper Number: NACE-2015-5894
... parallel trains of glycol dehydration units to remove the moisture before being exported. Recurring failures due to severe corrosion were reported in some of the heat exchangers in carbon steel material in all the trains of the dehydration units in two of the Gathering Centers. When further investigated...
Proceedings Papers

Paper presented at the CORROSION 2014, March 9–13, 2014
Paper Number: NACE-2014-4176
... ABSTRACT Monoethylene glycol (MEG) is injected in the pipelines to prevent hydrate formation, and subsequent pipeline blockage. Recent investigations indicated that presence of MEG could impede CO 2 corrosion of carbon steel, although many aspects remain unknown. In the current study...
Proceedings Papers

Paper presented at the CORROSION 2010, March 14–18, 2010
Paper Number: NACE-10277
... ABSTRACT Results from joint industry projects (JIP) on corrosion in sour wet gas pipelines with hydrate preventers (glycols) are presented and discussed. Experiments were run in flow loops and glass cell equipment with 0.1-5 bar CO 2 INTRODUCTION Many wet gas carbon steel pipelines worldwide...
Proceedings Papers

Paper presented at the CORROSION 2010, March 14–18, 2010
Paper Number: NACE-10129
... not only in aqueous systems but also in environments that contain nonaqueous additives such as methanol or mono-, di-, and triethylene glycols. The performance of the model has been analyzed for various solids including calcium sulfate, barium sulfate, calcium carbonate and magnesium carbonate...
Proceedings Papers

Paper presented at the CORROSION 2008, March 16–20, 2008
Paper Number: NACE-08419
... Subsurface Corrosion materials and corrosion Upstream Oil & Gas Pipeline Corrosion well integrity dehydration system amine Corrosion Problem lean rich exchanger amine plant Hydrogen Sulfide reboiler flowline corrosion riser corrosion carbon dioxide glycol dehydration system...
Proceedings Papers

Paper presented at the CORROSION 2007, March 11–15, 2007
Paper Number: NACE-07397
... water in liquid and vapor phase, contaminants such as chlorides will also be absorbed especially by glycol fluid if it used as dehydration system. Furthermore, the glycol will dissolve other gas contaminants including carbon dioxide, hydrogen sulfide, and some heavy hydrocarbons. Gas dehydration...
Proceedings Papers

Paper presented at the CORROSION 2006, March 12–16, 2006
Paper Number: NACE-06447
... ABSTRACT Ethylene glycol is often used worldwide in both plants and pipelines to prevent hydrate formation. Worldwide, there are several offshore wet gas pipelines that transport gas through large distances, under hydrate forming conditions with large concentrations of acid gas. Several...
Proceedings Papers

Paper presented at the CORROSION 2006, March 12–16, 2006
Paper Number: NACE-06442
... POSSIBLE GLYCOL CORROSION IN NOMINALLY DRY GAS PIPELINES John S. Smart, III John Smart Consulting Engineers Houston, TX 77079 Tel 281 493 5946 email [email protected] Randy Roberts HCR Coastal Chemical POB 81577 Lafayette, LA 70598-1577 Tel 337 333 1522 email [email protected]...
Proceedings Papers

Paper presented at the CORROSION 2005, April 3–7, 2005
Paper Number: NACE-05278
... such as the presence of mono-ethylene glycol (MEG) and the use of pH control were studied in a 4 diameter flow loop. Two sets of experiments were conducted; one at 70ºC, high CO2 partial pressure and a critical condensation rate and another one at 80ºC, low CO2 partial pressure and a high condensation rate. Weight...
Proceedings Papers

Paper presented at the CORROSION 2005, April 3–7, 2005
Paper Number: NACE-05305
... ABSTRACT Monoethylene glycol (MEG) is often used to prevent formation of solid gas-hydrates in wet natural gas pipelines when low operating temperatures are expected (e.g. sealines). Glycols have a slightly inhibiting effect on CO2 corrosion, however, corrosion control methods such as pH...
Proceedings Papers

Paper presented at the CORROSION 2004, March 28–April 1, 2004
Paper Number: NACE-04119
... was evacuated in a carbon steel pipeline to the Frigg Field for further processing. In order to protect the pipeline against internal corrosion, injection of a pH stabilizer mixed with glycol was implemented. Formation water arrived early in the production lifetime and a switch from pH stabilizer...
Proceedings Papers

Paper presented at the CORROSION 2004, March 28–April 1, 2004
Paper Number: NACE-04177
... glycol corrosion mechanism sediment side stream monitor oxygen coupon INTERNAL CORROSION DIRECT MEASUREMENT ENHANCES PIPELINE INTEGRITY John S. Smart John Smart Consulting Engineers 14210 Carolcrest Drive Houston, TX 77079 Thomas Pickthall Enhanceco, Inc P. O. Box 747 Stafford, TX 77497 SUMMARY...
Proceedings Papers

Paper presented at the CORROSION 2004, March 28–April 1, 2004
Paper Number: NACE-04322
... system treatment program. Keywords: cleaning, closed system, filtration, glycol, molybdate, nitrite. INTRODUCTION Hot and chilled (closed) water systems are found in many applications, ranging from space heating in commercial and industrial sites, to residential applications, as well as providing cooling...
Proceedings Papers

Paper presented at the CORROSION 2004, March 28–April 1, 2004
Paper Number: NACE-04422
... Pipeline Corrosion flowline corrosion well integrity corrosion inhibitor riser corrosion Subsurface Corrosion corrosion rate corrosion inhibitor development MEG Brine composition glycol materials and corrosion Upstream Oil & Gas platform nace international corrosion conference...

Product(s) added to cart