Skip Nav Destination
Close Modal
Update search
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- EISBN
- ISSN
- EISSN
- Issue
- Volume
- References
- Paper Number
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- EISBN
- ISSN
- EISSN
- Issue
- Volume
- References
- Paper Number
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- EISBN
- ISSN
- EISSN
- Issue
- Volume
- References
- Paper Number
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- EISBN
- ISSN
- EISSN
- Issue
- Volume
- References
- Paper Number
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- EISBN
- ISSN
- EISSN
- Issue
- Volume
- References
- Paper Number
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- EISBN
- ISSN
- EISSN
- Issue
- Volume
- References
- Paper Number
NARROW
Format
Subjects
Article Type
Date
Availability
1-9 of 9
Keywords: electrical continuity
Close
Follow your search
Access your saved searches in your account
Would you like to receive an alert when new items match your search?
Sort by
Proceedings Papers
Publisher: NACE International
Paper presented at the CORROSION 2019, March 24–28, 2019
Paper Number: NACE-2019-13003
... into confined spaces. Indirect assessment techniques, particularly the over-the-line potential surveys for condition assessment of water/wastewater lines can be conducted to determine active external corrosion areas. Traditionally, over-the-line potential surveys were applied to electrically continuous...
Proceedings Papers
Publisher: NACE International
Paper presented at the CORROSION 2018, April 15–19, 2018
Paper Number: NACE-2018-11064
... and to be demolished and replaced. The pipeline was expected to be under impressed current cathodic protection (CP), but historical data showed that the CP system was not fully functional for several years. Additionally electrical continuity could not be verified with high certainty along the entire the segment due...
Proceedings Papers
Publisher: NACE International
Paper presented at the CORROSION 2009, March 22–26, 2009
Paper Number: NACE-09064
... chemistry subsea system electrical continuity current density Corrosion Management protection deep water consideration Gulf H2S management calcareous deposit coating application Production Chemistry CP design water depth cathodic protection design consideration Design Consideration...
Proceedings Papers
Publisher: NACE International
Paper presented at the CORROSION 2007, March 11–15, 2007
Paper Number: NACE-07366
... flows, in which the electrical continuity between the electrodes was intermittently lost, only the EN technique was able to provide reliable values of R p . INTRODUCTION The accurate in-situ measurement of corrosion rates in industrial plants is one of the most important inputs of a preventive...
Proceedings Papers
Publisher: NACE International
Paper presented at the CORROSION 2006, March 12–16, 2006
Paper Number: NACE-06106
... and fabrication. The verification of electrical continuity is an important step in the fabrication of the equipment that has implications on the corrosion protection and integrity of the equipment. INTRODUCTION Tahoe I was a single satellite gas well in 1,500 FSW (feet of seawater) (460 m) that produced back...
Proceedings Papers
Publisher: NACE International
Paper presented at the CORROSION 2005, April 3–7, 2005
Paper Number: NACE-05244
... welding of the reinforcing steel (rebar) for electrical continuity, coatings and waterproofing membranes, test facilities, and grounding methods. Due to the complexity of the reinforcing steel configuration within concrete bridge structures, the stray current control designs described herein are general...
Proceedings Papers
Publisher: NACE International
Paper presented at the CORROSION 2004, March 28–April 1, 2004
Paper Number: NACE-04350
... for masonry-clad, steel-framed buildings may consist of the following basic components: DC power supply (distributed rectifier system). Inert anode material, such as catalyzed titanium ribbon mesh or titanium rods. Electrical continuity bonding of steel components. DC wiring between the anode, steel...
Proceedings Papers
Publisher: NACE International
Paper presented at the CORROSION 99, April 25–30, 1999
Paper Number: NACE-99547
..., half-cell potential mapping, concrete electrical resistivity measurements, and electrical continuity testing of the steel reinforcement. Results fi-om the visual inspection confirmed that all of the piles displayed various levels of corrosion induced damage. This was characterized by cracks and rust...
Proceedings Papers
Publisher: NACE International
Paper presented at the CORROSION 98, March 22–27, 1998
Paper Number: NACE-98558
... on timber ties and crushed stone ballast. Ties will be treated to minimize water absorption. All the rails will have welded rather than bolted connections. In the past, bolted connections were common. These were bonded to increase electrical continuity, but often bonds broke or became loose and a high...