Proceedings Papers

Paper presented at the CORROSION 2007, March 11–15, 2007
Paper Number: NACE-07443
... in the boiler. Failed carbon steel boiler tubes from different kraft recovery boilers were examined to understand the role of carbon steel microstructure on crack initiation and SAC crack morphology. A number of carbon steel tubes showed a deep decarburized layer on the inner surface (water-touched) and also...
Proceedings Papers

Paper presented at the CORROSION 2006, March 12–16, 2006
Paper Number: NACE-06241
... ABSTRACT Industrial boilers like kraft recovery boilers experience stress assisted corrosion (SAC) cracks in their carbon steel tubes and other water touched surfaces. The performance of carbon steel in industrial boilers strongly depends upon the formation and stability of the protective...