1-20 of 28
Keywords: icd
Close
Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Proceedings Papers

Paper presented at the International Petroleum Technology Conference, February 18–20, 2025
Paper Number: IPTC-25012-EA
... Abstract The oil & gas industry has adopted intelligent completions with Inflow Control Devices (ICDs) extensively to achieve selective production and water control from various zones of a single reservoir. The conventional method to modify the opening/closing state of these ICDs involves...
Proceedings Papers

Paper presented at the International Petroleum Technology Conference, February 12, 2024
Paper Number: IPTC-24444-MS
... The proposed workflow to model numerically ICD completions in this paper, as shown in Fig.3 , stars with the basic reservoir inputs (reservoir pressure and temperature, rock and fluid PVT properties) required by any commercial pressure transient analysis software package equipped with an ICD...
Proceedings Papers

Paper presented at the International Petroleum Technology Conference, February 12, 2024
Paper Number: IPTC-23178-EA
... across valves and orifices presented in complex lower completions, e.g., Limited Entry Liners (LEL), Inflow Control Devices (ICDs), and Inflow Control Valves (ICVs). The acid is distributed in the openhole-liner annulus based on the flow rate through the orifice/valve, annulus flow area, packers location...
Proceedings Papers

Paper presented at the International Petroleum Technology Conference, February 12, 2024
Paper Number: IPTC-23556-EA
... Table-1 Produced water handling & disposal costs (The costs need inflation adjustment) (After Jackson and Myers 2003) Table-2 Comparison of various ICD shifting options Table-3 Recommended ICD Positions Table-4 Recommended ICD...
Proceedings Papers

Paper presented at the International Petroleum Technology Conference, February 12, 2024
Paper Number: IPTC-24385-MS
... Abstract The objective of this paper is to present learnings from designing inflow control devices (ICD) of numerous wells at reservoirs with gas cap with various settings. Key aspects and an efficient ICD design workflow will be presented. The evaluation is based on the application of nozzle...
Proceedings Papers

Paper presented at the International Petroleum Technology Conference, March 1–3, 2023
Paper Number: IPTC-23007-MS
... Abstract In Q4 2017, the first extended-reach horizontal oil producer was completed in S-Field, with the horizontal section designed with nine isolation compartments with swellable packers. Each compartment was configured with an inflow control device (ICD) and an integral sleeve (on/off...
Proceedings Papers

Paper presented at the International Petroleum Technology Conference, March 23–April 1, 2021
Paper Number: IPTC-21189-MS
... enhanced recovery artificial intelligence modeling & simulation flow control equipment optimization problem reservoir simulation completion equipment upstream oil & gas optimization result subsurface control simulation result optimization contribution icd workflow fcv fcd advanced...
Proceedings Papers

Paper presented at the International Petroleum Technology Conference, March 23–April 1, 2021
Paper Number: IPTC-21450-MS
.... Figure 4 AICV mounted into sand screen joint. Figure 6 Comparison of single-phase flow performance of the ICD and AICV for oil, water, and gas. Figure 7 Two-phase behavior of AICV and ICD in the GVF range over 60%. Figure 8 Two-phase behavior of AICV in the GVF range from...
Proceedings Papers

Paper presented at the International Petroleum Technology Conference, January 13–15, 2020
Paper Number: IPTC-19718-MS
... are experienced after screen installation, isolating the open hole with a fluid loss control valve can take a long time. This paper describes a washpipe-free solution for screen installation using a check valve ICD. ICD screens are commonly used to delay/restrict influx of unwanted fluids such as gas or water...
Proceedings Papers

Paper presented at the International Petroleum Technology Conference, January 13–15, 2020
Paper Number: IPTC-20195-ABSTRACT
... with a free gas production. The AICV combines the best from passive inflow control device (ICD), Autonomous ICD and smart wells (ICV). This fit for purpose technology allows for autonomous oil re-production after gas breakthrough with minimal surface intervention. The AICV design is adapted to the reservoir...
Proceedings Papers

Paper presented at the International Petroleum Technology Conference, January 13–15, 2020
Paper Number: IPTC-20297-MS
... using an equalizer completion consisting of inflow control devices (ICDs) and isolating them through openhole packers and constrictors. This helps to eliminate the imbalanced production in the wellbore avoiding early water breakthrough. Currently, two kinds of ICDs are used, passive and adaptive...
Proceedings Papers

Paper presented at the International Petroleum Technology Conference, March 26–28, 2019
Paper Number: IPTC-19450-MS
... Control Device (ICD) design. This paper highlights the potentials of such customized ICD's innovation with integral sliding sleeve. This novel ICD design preserves intended ICD position, and in addition could be shifted in the downhole later either to be in open or closed position if required. Either...
Proceedings Papers

Paper presented at the International Petroleum Technology Conference, November 14–16, 2016
Paper Number: IPTC-18939-MS
... (Field A and Field B); these key design factors included: Well completion design to maximize zonal production contribution through use of Inflow Control Devices (ICDs) or Interval Control Valves (ICVs) to improve sweep efficiency Fit for purpose well material selection for injectors and oil...
Proceedings Papers

Paper presented at the International Petroleum Technology Conference, December 10–12, 2014
Paper Number: IPTC-18002-MS
... Abstract Static inflow control devices (ICDs) have been designed to provide a more even inflow across production zones by adjusting the completion pressure differential to balance reservoir drawdown. Unwanted fluids are delayed, oil production is enhanced. Recently, companies have offered...
Proceedings Papers

Paper presented at the International Petroleum Technology Conference, December 10–12, 2014
Paper Number: IPTC-17776-MS
... to the limited flow contribution from the non-coning regions. Inflow control devices (ICD) are installed to maintain the flow across production zones uniformly by creating an additional pressure differential which cancels out the imbalanced production profile. This will lower startup production, however...
Proceedings Papers

Paper presented at the International Petroleum Technology Conference, December 10–12, 2014
Paper Number: IPTC-17753-MS
... recovery per well in thin oil-rim reservoirs with varying reservoir complexity and uncertainties. 45 horizontal wells were progressively drilled and all completed with ICD in a relatively flat thin oil-rim reservoir offshore in peninsular Malaysia. In this successful oil development, well path between...
Proceedings Papers

Paper presented at the International Petroleum Technology Conference, December 10–12, 2014
Paper Number: IPTC-17794-MS
... to the limited flow contribution from the non-coning regions. Inflow control devices (ICDs) are installed to maintain the flow across production zones uniformly by creating an additional pressure drop which cancels out the imbalanced production profile. Since a typical well with ICDs can be in production from 5...
Proceedings Papers

Paper presented at the International Petroleum Technology Conference, March 26–28, 2013
Paper Number: IPTC-16872-MS
... of downhole inflow imbalance along the entire horizontal wellbore is much worse in fractured reservoir due to the high contrast in permeability between macro fractures, micro-fractures and the core matrix inflow. In order to provide an inflow-control defense system downhole, ICD's application has been tested...

Product(s) added to cart

Close Modal